Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Miami |
---|---|
Assessment Year | 2006 |
Principal Product | fire hose |
NAICS | 313220 - Narrow Fabric Mills and Schiffli Machine Embroidery |
SIC | 2241 - Narrow Fabric Mills |
Sales | $10,000,000-$50,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 100,000 |
Annual Production | 21,000 Thousand Feet |
Production Hrs. Annual | 7,350 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $82,701 | 1,461,900 | kWh | $0.06 |
Electricity Demand | $29,877 | 3,711 | kW-months/year | $8.05 |
Electricity Fees | $13,070 | - | $ | - |
Natural Gas | $110,892 | 7,215 | MMBtu | $15.37 |
TOTAL ENERGY COSTS | $236,540 | |||
RECOMMENDED SAVINGS* | $77,484 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $77,484 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Primary Raw Material | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Primary Raw Material | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $17,617 Cost: $16,000 |
- | - | - | - | $17,617 | 1,144 | - | - | - | - |
- - kWh |
- - kW-months/year |
$17,617 1,144 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $8,323 Cost: $1,020 |
- | - | - | - | $8,323 | 541 | - | - | - | - |
- - kWh |
- - kW-months/year |
$8,323 541 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $6,331 Cost: $212 |
$4,990 | 88,200 | $861 | 144 | - | - | - | - | $480 | - |
$4,990 88,200 kWh |
$861 144 kW-months/year |
- - MMBtu |
- - $ |
$480 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $1,497 Cost: $1,750 |
- | - | - | - | $1,497 | 97 | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,497 97 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,474 Cost: - |
$1,440 | 25,715 | $34 | 4 | - | - | - | - | - | - |
$1,440 25,715 kWh |
$34 4 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.131 MODIFY PROCESS TO REDUCE MATERIAL USE/COST |
Savings: $42,242 Cost: $140 |
$242 | 4,307 | - | - | - | - | $42,000 | - | - | - |
$242 4,307 kWh |
- - kW-months/year |
- - MMBtu |
$42,000 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $77,484 Cost: $19,122 |
$6,672 | 118,222 | $895 | 148 | $27,437 | 1,782 | $42,000 | - | $480 | - | $6,672 118,222 kWh |
$895 148 kW-months/year |
$27,437 1,782 MMBtu |
$42,000 - $ |
$480 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $77,484 Cost: $19,122 |
$6,672 | 118,222 | $895 | 148 | $27,437 | 1,782 | $42,000 | - | $480 | - | $6,672 118,222 kWh |
$895 148 kW-months/year |
$27,437 1,782 MMBtu |
$42,000 - $ |
$480 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Primary Raw Material | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Primary Raw Material | Ancillary Material Cost |