IAC logo
IAC Assessment: MI0181
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: MI0181
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Miami
Assessment Year 2009
Principal Product Pacemakers
NAICS 334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing
SIC 3845 - Electromedical Equipment
Sales $50,000,000-$100,000,000
# of Employees 200
Plant Area (Sq.Ft.) 125,000
Annual Production 25,000 Units
Production Hrs. Annual 4,590
Location (State) PR
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $2,770,160 15,493,680 kWh $0.18
Electricity Demand $219,483 28,504 kW-months/year $7.70
Electricity Fees $450 - $ -
TOTAL ENERGY COSTS $2,990,093
RECOMMENDED SAVINGS* $480,699 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $416,361
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$218,599
Cost:
$25,000
$192,927 1,105,209 $25,672 3,334 $192,927
1,105,209
kWh
$25,672
3,334
kW-months/year
02: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$143,524
Cost:
$2,000
$135,183 773,460 $8,341 1,083 $135,183
773,460
kWh
$8,341
1,083
kW-months/year
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$62,935
Cost:
$60,000
$59,208 338,748 $3,727 484 $59,208
338,748
kWh
$3,727
484
kW-months/year
04: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$50,254
Cost:
$2,000
$47,333 270,820 $2,921 379 $47,333
270,820
kWh
$2,921
379
kW-months/year
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$3,674
Cost:
$1,210
$2,366 13,540 $1,308 170 $2,366
13,540
kWh
$1,308
170
kW-months/year
06: 2.4323 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT Savings:
$1,403
Cost:
$4,531
$1,243 7,112 $160 83 $1,243
7,112
kWh
$160
83
kW-months/year
07: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$310
Cost:
$40
$234 2,117 $76 26 $234
2,117
kWh
$76
26
kW-months/year
TOTAL RECOMMENDED Savings:
$480,699
Cost:
$94,781
$438,494 2,511,006 $42,205 5,559 $438,494
2,511,006
kWh
$42,205
5,559
kW-months/year
TOTAL IMPLEMENTED Savings:
$416,361
Cost:
$30,250
$378,043 2,165,146 $38,318 4,992 $378,043
2,165,146
kWh
$38,318
4,992
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand