Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Miami |
---|---|
Assessment Year | 2009 |
Principal Product | Pacemakers |
NAICS | 334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing |
SIC | 3845 - Electromedical Equipment |
Sales | $50,000,000-$100,000,000 |
# of Employees | 200 |
Plant Area (Sq.Ft.) | 125,000 |
Annual Production | 25,000 Units |
Production Hrs. Annual | 4,590 |
Location (State) | PR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $2,770,160 | 15,493,680 | kWh | $0.18 |
Electricity Demand | $219,483 | 28,504 | kW-months/year | $7.70 |
Electricity Fees | $450 | - | $ | - |
TOTAL ENERGY COSTS | $2,990,093 | |||
RECOMMENDED SAVINGS* | $480,699 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $416,361 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Usage | Electricity Demand | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $218,599 Cost: $25,000 |
$192,927 | 1,105,209 | $25,672 | 3,334 |
$192,927 1,105,209 kWh |
$25,672 3,334 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $143,524 Cost: $2,000 |
$135,183 | 773,460 | $8,341 | 1,083 |
$135,183 773,460 kWh |
$8,341 1,083 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $62,935 Cost: $60,000 |
$59,208 | 338,748 | $3,727 | 484 |
$59,208 338,748 kWh |
$3,727 484 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $50,254 Cost: $2,000 |
$47,333 | 270,820 | $2,921 | 379 |
$47,333 270,820 kWh |
$2,921 379 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,674 Cost: $1,210 |
$2,366 | 13,540 | $1,308 | 170 |
$2,366 13,540 kWh |
$1,308 170 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4323 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT |
Savings: $1,403 Cost: $4,531 |
$1,243 | 7,112 | $160 | 83 |
$1,243 7,112 kWh |
$160 83 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $310 Cost: $40 |
$234 | 2,117 | $76 | 26 |
$234 2,117 kWh |
$76 26 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $480,699 Cost: $94,781 |
$438,494 | 2,511,006 | $42,205 | 5,559 | $438,494 2,511,006 kWh |
$42,205 5,559 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $416,361 Cost: $30,250 |
$378,043 | 2,165,146 | $38,318 | 4,992 | $378,043 2,165,146 kWh |
$38,318 4,992 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Usage | Electricity Demand |