Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Miami |
---|---|
Assessment Year | 2010 |
Principal Product | Airplane |
NAICS | 336411 - Aircraft Manufacturing |
SIC | 3721 - Aircraft |
Sales | $100,000,000-$500,000,000 |
# of Employees | 450 |
Plant Area (Sq.Ft.) | 700,000 |
Annual Production | 300 Pieces |
Production Hrs. Annual | 4,335 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $636,510 | 12,815,564 | kWh | $0.05 |
Electricity Demand | $178,678 | 39,732 | kW-months/year | $4.50 |
Electricity Fees | $1,057,095 | - | $ | - |
TOTAL ENERGY COSTS | $1,872,283 | |||
RECOMMENDED SAVINGS* | $429,974 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $300,235 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Usage | Electricity Demand | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD |
Savings: $157,910 Cost: $102,500 |
$145,494 | 996,537 | $12,416 | 2,759 |
$145,494 996,537 kWh |
$12,416 2,759 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD |
Savings: $113,486 Cost: $143,892 |
$104,565 | 716,196 | $8,921 | 1,983 |
$104,565 716,196 kWh |
$8,921 1,983 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $108,082 Cost: $2,000 |
$99,585 | 682,091 | $8,497 | 1,888 |
$99,585 682,091 kWh |
$8,497 1,888 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $34,243 Cost: $1,210 |
$32,605 | 223,321 | $1,638 | 364 |
$32,605 223,321 kWh |
$1,638 364 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $12,467 Cost: $40 |
$11,330 | 77,604 | $1,137 | 253 |
$11,330 77,604 kWh |
$1,137 253 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4323 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT |
Savings: $3,786 Cost: $4,531 |
$3,609 | 24,717 | $177 | 40 |
$3,609 24,717 kWh |
$177 40 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $429,974 Cost: $254,173 |
$397,188 | 2,720,466 | $32,786 | 7,287 | $397,188 2,720,466 kWh |
$32,786 7,287 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $300,235 Cost: $105,710 |
$277,684 | 1,901,949 | $22,551 | 5,011 | $277,684 1,901,949 kWh |
$22,551 5,011 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Usage | Electricity Demand |