IAC logo
IAC Assessment: MI0441
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: MI0441
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Miami
Assessment Year 2024
Principal Product Peptones and Amino Acids
NAICS 325199 - All Other Basic Organic Chemical Manufacturing
SIC 2869 - Industrial Organic Chemicals, Nec
Sales $100,000,000-$500,000,000
# of Employees 100
Plant Area (Sq.Ft.) 77,897
Annual Production 500,000 Pounds
Production Hrs. Annual 5,880
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $166,500 2,676,960 kWh $0.06
Electricity Demand $98,908 6,576 kW-months/year $15.04
Electricity Fees $54,311 - $ -
Natural Gas $130,778 45,182 MMBtu $2.89
TOTAL ENERGY COSTS $625,716
RECOMMENDED SAVINGS* $110,453 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Water Disposal Administrative Changes Electricity Usage Electricity Demand Natural Gas Water Disposal Administrative Changes
$ kWh $ kW-months/year $ MMBtu $ Tgal $ $
01: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL Savings:
$58,244
Cost:
$186,000
$38,957 628,337 $19,287 1,282 - - - - - - $38,957
628,337
kWh
$19,287
1,282
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
$
02: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$24,362
Cost:
$840
$16,615 267,977 $8,227 547 - - - - $(-480) - $16,615
267,977
kWh
$8,227
547
kW-months/year
-
-
MMBtu
-
-
Tgal
$(-480)
-
$
03: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) Savings:
$21,427
Cost:
$1,306
- - - - - - $21,427 1,440 - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$21,427
1,440
Tgal
-
-
$
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$2,377
Cost:
$510
$1,760 28,380 $617 41 - - - - - - $1,760
28,380
kWh
$617
41
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
$
05: 2.9112 USE SOLAR HEAT TO HEAT WATER Savings:
$2,247
Cost:
$2,602
- - - - $3,847 1,331 - - $(-1,600) - -
-
kWh
-
-
kW-months/year
$3,847
1,331
MMBtu
-
-
Tgal
$(-1,600)
-
$
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,124
Cost:
$1,980
$831 13,407 $293 20 - - - - - - $831
13,407
kWh
$293
20
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
$
07: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$671
Cost:
$1,203
$671 10,821 - - - - - - - - $671
10,821
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
$
TOTAL RECOMMENDED Savings:
$110,453
Cost:
$194,441
$58,834 948,922 $28,424 1,890 $3,847 1,331 $21,427 1,440 $(-2,080) - $58,834
948,922
kWh
$28,424
1,890
kW-months/year
$3,847
1,331
MMBtu
$21,427
1,440
Tgal
$(-2,080)
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ Tgal $ $
Electricity Usage Electricity Demand Natural Gas Water Disposal Administrative Changes Electricity Usage Electricity Demand Natural Gas Water Disposal Administrative Changes