Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Mississippi State |
---|---|
Assessment Year | 1996 |
Principal Product | Office partitions |
NAICS | n/a |
SIC | 2542 - Partitions And Fixtures, Except Wood |
Sales | $50,000,000-$100,000,000 |
# of Employees | 125 |
Plant Area (Sq.Ft.) | 257,000 |
Annual Production | 200,000 Pieces |
Production Hrs. Annual | 2,080 |
Location (State) | MS |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $147,407 | 4,752,052 | kWh | $0.03 |
Electricity Demand | $138,893 | 15,524 | kW-months/year | $8.95 |
Electricity Fees | $(-50,066) | - | $ | - |
Natural Gas | $37,047 | 12,038 | MMBtu | $3.08 |
TOTAL ENERGY COSTS | $307,636 | |||
RECOMMENDED SAVINGS* | $53,534 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $7,011 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | gal | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $4,277 Cost: $3,000 |
- | - | - | - | $4,277 | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$4,277 - $ |
- - MMBtu |
- - gal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $16,746 Cost: $10,140 |
$8,450 | 272,274 | $11,664 | 1,200 | - | - | $(-3,368) | (-929) | - | - | - | - | - | - |
$8,450 272,274 kWh |
$11,664 1,200 kW-months/year |
- - $ |
$(-3,368) (-929) MMBtu |
- - gal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2514 COVER OPEN TANKS |
Savings: $127 Cost: $304 |
- | - | - | - | - | - | $127 | 41 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$127 41 MMBtu |
- - gal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $2,734 Cost: $400 |
$975 | 31,360 | $1,759 | 181 | - | - | - | - | - | - | - | - | - | - |
$975 31,360 kWh |
$1,759 181 kW-months/year |
- - $ |
- - MMBtu |
- - gal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $2,749 Cost: $1,440 |
- | - | - | - | - | - | $2,749 | 892 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$2,749 892 MMBtu |
- - gal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,099 Cost: $300 |
$390 | 12,603 | $709 | 73 | - | - | - | - | - | - | - | - | - | - |
$390 12,603 kWh |
$709 73 kW-months/year |
- - $ |
- - MMBtu |
- - gal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $11,000 Cost: $6,500 |
- | - | - | - | - | - | - | - | - | - | $11,000 | 220,000 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - gal |
$11,000 220,000 lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.8142 DISTILL CONTAMINATED SOLVENTS FOR REUSE |
Savings: $14,802 Cost: - |
$(-172) | (-5,569) | $(-117) | (-12) | - | - | - | - | $17,691 | - | - | - | $(-2,600) | - |
$(-172) (-5,569) kWh |
$(-117) (-12) kW-months/year |
- - $ |
- - MMBtu |
$17,691 - gal |
- - lb |
$(-2,600) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $53,534 Cost: $22,084 |
$9,643 | 310,668 | $14,015 | 1,442 | $4,277 | - | $(-492) | 4 | $17,691 | - | $11,000 | 220,000 | $(-2,600) | - | $9,643 310,668 kWh |
$14,015 1,442 kW-months/year |
$4,277 - $ |
$(-492) 4 MMBtu |
$17,691 - gal |
$11,000 220,000 lb |
$(-2,600) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $7,011 Cost: $3,400 |
$975 | 31,360 | $1,759 | 181 | $4,277 | - | - | - | - | - | - | - | - | - | $975 31,360 kWh |
$1,759 181 kW-months/year |
$4,277 - $ |
- - MMBtu |
- - gal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | gal | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | Personnel Changes |