Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Mississippi State |
---|---|
Assessment Year | 1997 |
Principal Product | Poultry |
NAICS | n/a |
SIC | 2015 - Poultry Slaughtering And Processing |
Sales | $1,000,000-$5,000,000 |
# of Employees | 150 |
Plant Area (Sq.Ft.) | 31,000 |
Annual Production | 20,625,000 Pounds |
Production Hrs. Annual | 2,340 |
Location (State) | MS |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $137,030 | 4,288,101 | kWh | $0.03 |
Electricity Demand | $98,061 | 12,834 | kW-months/year | $7.64 |
Electricity Fees | $3,704 | - | $ | - |
Natural Gas | $91,581 | 24,960 | MMBtu | $3.67 |
TOTAL ENERGY COSTS | $485,177 | |||
RECOMMENDED SAVINGS* | $92,815 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Electricity Usage | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $6,500 Cost: $4,020 |
- | - | $6,500 | 1,771 | - | - | - | - | - | - |
- - kWh |
$6,500 1,771 MMBtu |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $7,888 Cost: $1,045 |
- | - | $7,888 | 2,149 | - | - | - | - | - | - |
- - kWh |
$7,888 2,149 MMBtu |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7231 USE RADIANT HEATER FOR SPOT HEATING |
Savings: $7,391 Cost: $2,890 |
- | - | $7,391 | 2,014 | - | - | - | - | - | - |
- - kWh |
$7,391 2,014 MMBtu |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $1,891 Cost: $982 |
- | - | $1,891 | 515 | - | - | - | - | - | - |
- - kWh |
$1,891 515 MMBtu |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $26,730 Cost: $6,040 |
- | - | $26,730 | 7,283 | - | - | - | - | - | - |
- - kWh |
$26,730 7,283 MMBtu |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $3,026 Cost: $2,316 |
$3,026 | 99,941 | - | - | - | - | - | - | - | - |
$3,026 99,941 kWh |
- - MMBtu |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $24,600 Cost: $6,500 |
- | - | - | - | $4,100 | 410,000 | - | - | $20,500 | - |
- - kWh |
- - MMBtu |
$4,100 410,000 lb |
- - $ |
$20,500 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.4155 METER WASTE WATER |
Savings: $2,434 Cost: $1,257 |
- | - | - | - | - | - | - | - | $2,434 | - |
- - kWh |
- - MMBtu |
- - lb |
- - $ |
$2,434 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.441 INSTALL AUTOMATIC PACKING EQUIPMENT |
Savings: $12,355 Cost: $17,000 |
- | - | - | - | - | - | $12,355 | - | - | - |
- - kWh |
- - MMBtu |
- - lb |
$12,355 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $92,815 Cost: $42,050 |
$3,026 | 99,941 | $50,400 | 13,732 | $4,100 | 410,000 | $12,355 | - | $22,934 | - | $3,026 99,941 kWh |
$50,400 13,732 MMBtu |
$4,100 410,000 lb |
$12,355 - $ |
$22,934 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - MMBtu |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Electricity Usage | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Administrative Changes |