Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Mississippi State |
---|---|
Assessment Year | 1999 |
Principal Product | Wooden Tables and Upholstered Furniture |
NAICS | n/a |
SIC | 2511 - Wood Household Furniture |
Sales | $10,000,000-$50,000,000 |
# of Employees | 260 |
Plant Area (Sq.Ft.) | 248,000 |
Annual Production | 387,000 Pieces |
Production Hrs. Annual | 2,500 |
Location (State) | MS |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $83,668 | 1,390,973 | kWh | $0.06 |
Electricity Demand | $54,458 | 8,848 | kW-months/year | $6.15 |
Electricity Fees | $3,020 | - | $ | - |
Natural Gas | $30,388 | 5,298 | MMBtu | $5.74 |
TOTAL ENERGY COSTS | $176,784 | |||
RECOMMENDED SAVINGS* | $371,545 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $3,444 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Administrative Changes | Ancillary Material Cost | Primary Product | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Administrative Changes | Ancillary Material Cost | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $441 Cost: $119 |
$435 | 13,482 | - | - | $6 | - | - | - | - | - | - | - | - | - |
$435 13,482 kWh |
- - kW-months/year |
$6 - $ |
- - $ |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $10,451 Cost: $11,700 |
- | - | - | - | $10,451 | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$10,451 - $ |
- - $ |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,511 Cost: $1,129 |
$2,473 | 75,909 | - | - | $38 | - | - | - | - | - | - | - | - | - |
$2,473 75,909 kWh |
- - kW-months/year |
$38 - $ |
- - $ |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $287 Cost: $217 |
$283 | 8,792 | - | - | $4 | - | - | - | - | - | - | - | - | - |
$283 8,792 kWh |
- - kW-months/year |
$4 - $ |
- - $ |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $933 Cost: $275 |
$241 | 7,327 | $541 | 45 | $12 | - | - | - | - | - | $139 | - | - | - |
$241 7,327 kWh |
$541 45 kW-months/year |
$12 - $ |
- - $ |
- - $ |
$139 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.511 EXPAND OPERATIONS INTO UNUSED SPACE |
Savings: $356,922 Cost: $862,280 |
- | - | - | - | $13,196 | - | $170,163 | - | $108,563 | - | - | - | $65,000 | - |
- - kWh |
- - kW-months/year |
$13,196 - $ |
$170,163 - $ |
$108,563 - $ |
- - $ |
$65,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $371,545 Cost: $875,720 |
$3,432 | 105,510 | $541 | 45 | $23,707 | - | $170,163 | - | $108,563 | - | $139 | - | $65,000 | - | $3,432 105,510 kWh |
$541 45 kW-months/year |
$23,707 - $ |
$170,163 - $ |
$108,563 - $ |
$139 - $ |
$65,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $3,444 Cost: $1,404 |
$2,714 | 83,236 | $541 | 45 | $50 | - | - | - | - | - | $139 | - | - | - | $2,714 83,236 kWh |
$541 45 kW-months/year |
$50 - $ |
- - $ |
- - $ |
$139 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Administrative Changes | Ancillary Material Cost | Primary Product | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Administrative Changes | Ancillary Material Cost | Primary Product |