Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Mississippi State |
---|---|
Assessment Year | 1999 |
Principal Product | Acoustic Ceiling Tiles |
NAICS | n/a |
SIC | 3296 - Mineral Wool |
Sales | $10,000,000-$50,000,000 |
# of Employees | 200 |
Plant Area (Sq.Ft.) | 450,000 |
Annual Production | 190,000 Thousand Feet |
Production Hrs. Annual | 7,728 |
Location (State) | MS |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $545,468 | 20,776,378 | kWh | $0.03 |
Electricity Demand | $184,032 | 40,896 | kW-months/year | $4.50 |
Electricity Fees | $80,024 | - | $ | - |
Natural Gas | $1,923,657 | 668,353 | MMBtu | $2.88 |
TOTAL ENERGY COSTS | $2,878,339 | |||
RECOMMENDED SAVINGS* | $71,835 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $68,182 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (haz) | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (haz) | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $3,484 Cost: $490 |
$694 | 106,975 | $788 | 175 | $2,002 | - | - | - | - | - | - | - |
$694 106,975 kWh |
$788 175 kW-months/year |
$2,002 - $ |
- - MMBtu |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $219 Cost: $591 |
$57 | 8,792 | - | - | $162 | - | - | - | - | - | - | - |
$57 8,792 kWh |
- - kW-months/year |
$162 - $ |
- - MMBtu |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2427 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS |
Savings: $61,739 Cost: $26,241 |
- | - | - | - | - | - | $61,739 | 21,724 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$61,739 21,724 MMBtu |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $6,224 Cost: $554 |
$1,610 | 247,948 | - | - | $4,614 | - | - | - | - | - | - | - |
$1,610 247,948 kWh |
- - kW-months/year |
$4,614 - $ |
- - MMBtu |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.7198 REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT |
Savings: $169 Cost: $574 |
- | - | - | - | - | - | - | - | $1 | 76 | $168 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$1 76 lb |
$168 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $71,835 Cost: $28,450 |
$2,361 | 363,715 | $788 | 175 | $6,778 | - | $61,739 | 21,724 | $1 | 76 | $168 | - | $2,361 363,715 kWh |
$788 175 kW-months/year |
$6,778 - $ |
$61,739 21,724 MMBtu |
$1 76 lb |
$168 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $68,182 Cost: $27,386 |
$1,667 | 256,740 | - | - | $4,776 | - | $61,739 | 21,724 | - | - | - | - | $1,667 256,740 kWh |
- - kW-months/year |
$4,776 - $ |
$61,739 21,724 MMBtu |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (haz) | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (haz) | Ancillary Material Cost |