Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Mississippi State |
---|---|
Assessment Year | 2000 |
Principal Product | Molded Plastic |
NAICS | n/a |
SIC | 3089 - Plastics Products, Nec |
Sales | $500,000-$1,000,000 |
# of Employees | 15 |
Plant Area (Sq.Ft.) | 43,600 |
Annual Production | 500,000 Pieces |
Production Hrs. Annual | 2,080 |
Location (State) | MS |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $32,497 | 782,400 | kWh | $0.04 |
Electricity Demand | $27,061 | 3,406 | kW-months/year | $7.95 |
Electricity Fees | $(-11,938) | - | $ | - |
TOTAL ENERGY COSTS | $49,120 | |||
RECOMMENDED SAVINGS* | $15,496 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $13,400 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $13,400 Cost: $50 |
- | - | - | - | $3,350 | - | $10,050 | - |
- - kWh |
- - kW-months/year |
$3,350 - $ |
$10,050 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $433 Cost: $186 |
$405 | 12,045 | - | - | $28 | - | - | - |
$405 12,045 kWh |
- - kW-months/year |
$28 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7122 DISCONNECT BALLASTS |
Savings: $272 Cost: $426 |
$82 | 2,437 | $173 | 17 | $17 | - | - | - |
$82 2,437 kWh |
$173 17 kW-months/year |
$17 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $55 Cost: $147 |
$51 | 1,517 | - | - | $4 | - | - | - |
$51 1,517 kWh |
- - kW-months/year |
$4 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $1,336 Cost: $2,385 |
- | - | - | - | $1,336 | - | - | - |
- - kWh |
- - kW-months/year |
$1,336 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $15,496 Cost: $3,194 |
$538 | 15,999 | $173 | 17 | $4,735 | - | $10,050 | - | $538 15,999 kWh |
$173 17 kW-months/year |
$4,735 - $ |
$10,050 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $13,400 Cost: $50 |
- | - | - | - | $3,350 | - | $10,050 | - | - - kWh |
- - kW-months/year |
$3,350 - $ |
$10,050 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | One-time Revenue or Avoided Cost |