IAC logo
IAC Assessment: MS0195
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: MS0195
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Mississippi State
Assessment Year 2001
Principal Product Aluminum cable
NAICS n/a
SIC 3357 - Nonferrous Wiredrawing & Insulating
Sales $10,000,000-$50,000,000
# of Employees 130
Plant Area (Sq.Ft.) 153,000
Annual Production 28,000,000 Pounds
Production Hrs. Annual 7,332
Location (State) MS
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $86,742 9,646,800 kWh $0.01
Electricity Demand $107,820 21,564 kW-months/year $5.00
Electricity Fees $239,834 - $ -
Natural Gas $97,954 18,970 MMBtu $5.16
TOTAL ENERGY COSTS $561,451
RECOMMENDED SAVINGS* $13,774 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $3,568
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Natural Gas Electricity Usage Electricity Demand Electricity Fees Natural Gas
$ kWh $ kW-months/year $ $ $ MMBtu
01: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$5,968
Cost:
$1,701
- - - - - - $5,968 1,167 -
-
kWh
-
-
kW-months/year
-
-
$
$5,968
1,167
MMBtu
02: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$3,494
Cost:
$1,000
- - - - - - $3,494 689 -
-
kWh
-
-
kW-months/year
-
-
$
$3,494
689
MMBtu
03: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$3,150
Cost:
$7,965
- - - - - - $3,150 621 -
-
kWh
-
-
kW-months/year
-
-
$
$3,150
621
MMBtu
04: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$1,088
Cost:
$51
$853 28,804 $219 44 $16 - - - $853
28,804
kWh
$219
44
kW-months/year
$16
-
$
-
-
MMBtu
05: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$74
Cost:
$119
$73 2,469 - - $1 - - - $73
2,469
kWh
-
-
kW-months/year
$1
-
$
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$13,774
Cost:
$10,836
$926 31,273 $219 44 $17 - $12,612 2,477 $926
31,273
kWh
$219
44
kW-months/year
$17
-
$
$12,612
2,477
MMBtu
TOTAL IMPLEMENTED Savings:
$3,568
Cost:
$1,119
$73 2,469 - - $1 - $3,494 689 $73
2,469
kWh
-
-
kW-months/year
$1
-
$
$3,494
689
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ $ $ MMBtu
Electricity Usage Electricity Demand Electricity Fees Natural Gas Electricity Usage Electricity Demand Electricity Fees Natural Gas