Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Mississippi State |
---|---|
Assessment Year | 2002 |
Principal Product | Mineral fiber products and acoustical tile |
NAICS | n/a |
SIC | 3296 - Mineral Wool |
Sales | $50,000,000-$100,000,000 |
# of Employees | 350 |
Plant Area (Sq.Ft.) | 958,323 |
Annual Production | 445,850 Thousand Feet |
Production Hrs. Annual | 6,240 |
Location (State) | MS |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $2,423,056 | 70,519,680 | kWh | $0.03 |
Electricity Fees | $685,501 | - | $ | - |
Natural Gas | $5,126,109 | 1,891,553 | MMBtu | $2.71 |
TOTAL ENERGY COSTS | $8,234,666 | |||
RECOMMENDED SAVINGS* | $1,136,306 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $119,155 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2442 PREHEAT COMBUSTION AIR WITH WASTE HEAT |
Savings: $529,152 Cost: $198,480 |
- | - | - | - | - | - | $529,152 | 195,259 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$529,152 195,259 MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $425,529 Cost: $1,452,000 |
$546,736 | 15,912,000 | $130,257 | 22,828 | $115,069 | - | $(-366,533) | (-125,252) | - | - |
$546,736 15,912,000 kWh |
$130,257 22,828 kW-months/year |
$115,069 - $ |
$(-366,533) (-125,252) MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $67,886 Cost: $1,950 |
$65,936 | 1,918,965 | - | - | $1,950 | - | - | - | - | - |
$65,936 1,918,965 kWh |
- - kW-months/year |
$1,950 - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $44,270 Cost: $30,411 |
$28,773 | 837,400 | $9,175 | 1,608 | $6,322 | - | - | - | - | - |
$28,773 837,400 kWh |
$9,175 1,608 kW-months/year |
$6,322 - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7311 VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE |
Savings: $23,617 Cost: $1,500 |
$19,961 | 580,949 | - | - | $3,656 | - | - | - | - | - |
$19,961 580,949 kWh |
- - kW-months/year |
$3,656 - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $20,902 Cost: $97 |
$14,549 | 423,423 | $3,309 | 580 | $3,044 | - | - | - | - | - |
$14,549 423,423 kWh |
$3,309 580 kW-months/year |
$3,044 - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $3,779 Cost: $1,113 |
$3,194 | 92,951 | - | - | $585 | - | - | - | - | - |
$3,194 92,951 kWh |
- - kW-months/year |
$585 - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,971 Cost: $696 |
$2,511 | 73,089 | - | - | $460 | - | - | - | - | - |
$2,511 73,089 kWh |
- - kW-months/year |
$460 - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.5316 CONTRACT A WOOD PALLET RECYCLING COMPANY |
Savings: $18,200 Cost: - |
- | - | - | - | - | - | - | - | $18,200 | 104,000 |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$18,200 104,000 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $1,136,306 Cost: $1,686,247 |
$681,660 | 19,838,777 | $142,741 | 25,016 | $131,086 | - | $162,619 | 70,007 | $18,200 | 104,000 | $681,660 19,838,777 kWh |
$142,741 25,016 kW-months/year |
$131,086 - $ |
$162,619 70,007 MMBtu |
$18,200 104,000 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $119,155 Cost: $5,356 |
$106,151 | 3,089,377 | $3,309 | 580 | $9,695 | - | - | - | - | - | $106,151 3,089,377 kWh |
$3,309 580 kW-months/year |
$9,695 - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) |