Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Mississippi State
Assessment Year 2022
Principal Product Air Handlers
NAICS 333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipmen
SIC 3585 - Refrigeration And Heating Equipment
Sales $50,000,000-$100,000,000
# of Employees 230
Plant Area (Sq.Ft.) 12,850
Annual Production 461 Units
Production Hrs. Annual 4,800
Location (State) MS
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $223,483 2,379,600 kWh $0.09
Electricity Demand $11,665 5,884 kW-months/year $1.98
Electricity Fees $2,739 - $ -
Natural Gas $23,055 1,974 MMBtu $11.68
TOTAL ENERGY COSTS $260,941
RECOMMENDED SAVINGS* $82,198 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$357
Cost:
$1,634
$357 3,802 - - - - $357
3,802
kWh
-
-
kW-months/year
-
-
MMBtu
02: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$70,508
Cost:
$548,100
$70,508 750,084 - - - - $70,508
750,084
kWh
-
-
kW-months/year
-
-
MMBtu
03: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$3,817
Cost:
-
$3,774 40,146 $43 22 - - $3,774
40,146
kWh
$43
22
kW-months/year
-
-
MMBtu
04: 2.1321 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT Savings:
$2,092
Cost:
$12,955
$(-973) (-10,353) - - $3,065 262 $(-973)
(-10,353)
kWh
-
-
kW-months/year
$3,065
262
MMBtu
05: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$5,424
Cost:
-
$5,424 57,707 - - - - $5,424
57,707
kWh
-
-
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$82,198
Cost:
$562,689
$79,090 841,386 $43 22 $3,065 262 $79,090
841,386
kWh
$43
22
kW-months/year
$3,065
262
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas