IAC logo
IAC Assessment: MU0053
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: MU0053
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Michigan State University
Assessment Year 2024
Principal Product Polyethylene Film
NAICS 326111 - Plastics Bag and Pouch Manufacturing
SIC 2673 - Bags: Plastics, Laminated, & Coated
Sales $10,000,000-$50,000,000
# of Employees 135
Plant Area (Sq.Ft.) 92,000
Annual Production 26,280,345 Pounds
Production Hrs. Annual 8,712
Location (State) MI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $663,128 9,679,200 kWh $0.07
Electricity Demand $238,429 16,067 kW-months/year $14.84
Electricity Fees $10,866 - $ -
Natural Gas $73,279 8,630 MMBtu $8.49
Other Gas $9,300 1 MMBtu $9,300.01
TOTAL ENERGY COSTS $995,003
RECOMMENDED SAVINGS* $109,265 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$456
Cost:
$1,958
$244 3,488 $212 14 - - $244
3,488
kWh
$212
14
kW-months/year
-
-
MMBtu
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$439
Cost:
$51
$316 4,511 $123 8 - - $316
4,511
kWh
$123
8
kW-months/year
-
-
MMBtu
03: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$1,429
Cost:
$4,900
$494 7,057 $935 63 - - $494
7,057
kWh
$935
63
kW-months/year
-
-
MMBtu
04: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$79,472
Cost:
$58,598
$61,516 878,804 $17,956 1,210 - - $61,516
878,804
kWh
$17,956
1,210
kW-months/year
-
-
MMBtu
05: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$7,196
Cost:
$1,904
$5,580 79,719 $1,616 109 - - $5,580
79,719
kWh
$1,616
109
kW-months/year
-
-
MMBtu
06: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$955
Cost:
-
$698 9,970 $257 17 - - $698
9,970
kWh
$257
17
kW-months/year
-
-
MMBtu
07: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED Savings:
$1,119
Cost:
-
$867 12,379 $252 17 - - $867
12,379
kWh
$252
17
kW-months/year
-
-
MMBtu
08: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$865
Cost:
$512
$672 9,605 $193 13 - - $672
9,605
kWh
$193
13
kW-months/year
-
-
MMBtu
09: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$90
Cost:
-
$64 911 $27 2 - - $64
911
kWh
$27
2
kW-months/year
-
-
MMBtu
10: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS Savings:
$16,560
Cost:
$17,565
$16,753 622,833 $(-193) (-13) - - $16,753
622,833
kWh
$(-193)
(-13)
kW-months/year
-
-
MMBtu
11: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$473
Cost:
$140
$366 5,227 $107 7 - - $366
5,227
kWh
$107
7
kW-months/year
-
-
MMBtu
12: 2.7492 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE Savings:
$210
Cost:
$546
- - - - $210 26 -
-
kWh
-
-
kW-months/year
$210
26
MMBtu
TOTAL RECOMMENDED Savings:
$109,265
Cost:
$86,174
$87,570 1,634,504 $21,486 1,448 $210 26 $87,570
1,634,504
kWh
$21,486
1,448
kW-months/year
$210
26
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas