IAC logo
IAC Assessment: MU0069
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: MU0069
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Michigan State University
Assessment Year 2025
Principal Product Automotive Part Trays, Kayaks, Deer Blinds, and Kiddie pools
NAICS 326199 - All Other Plastics Product Manufacturing
SIC 3089 - Plastics Products, Nec
Sales $50,000,000-$100,000,000
# of Employees 177
Plant Area (Sq.Ft.) 270,000
Annual Production 2,000,000 Units
Production Hrs. Annual 8,760
Location (State) MI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $2,017,318 22,613,581 kWh $0.09
Electricity Demand $339,606 63,789 kW-months/year $5.32
Electricity Fees $26,849 - $ -
Natural Gas $79,731 12,525 MMBtu $6.37
Other Gas $4,371 1 MMBtu $4,371.10
TOTAL ENERGY COSTS $2,517,031
RECOMMENDED SAVINGS* $67,910 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$27,682
Cost:
$5,553
$25,558 287,127 $2,124 393 $25,558
287,127
kWh
$2,124
393
kW-months/year
02: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$24,311
Cost:
$129,488
$22,446 252,207 $1,865 345 $22,446
252,207
kWh
$1,865
345
kW-months/year
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$4,826
Cost:
$669
$4,456 50,065 $370 69 $4,456
50,065
kWh
$370
69
kW-months/year
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$4,011
Cost:
-
$3,703 41,607 $308 57 $3,703
41,607
kWh
$308
57
kW-months/year
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$674
Cost:
$120
$622 6,991 $52 10 $622
6,991
kWh
$52
10
kW-months/year
06: 2.6125 KEEP EQUIPMENT CLEAN Savings:
$3,684
Cost:
-
$3,401 38,215 $283 52 $3,401
38,215
kWh
$283
52
kW-months/year
07: 2.7134 USE PHOTOCELL CONTROLS Savings:
$1,214
Cost:
$754
$929 10,437 $285 53 $929
10,437
kWh
$285
53
kW-months/year
08: 2.7134 USE PHOTOCELL CONTROLS Savings:
$982
Cost:
-
$839 9,427 $143 26 $839
9,427
kWh
$143
26
kW-months/year
09: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$339
Cost:
$581
$313 3,514 $26 5 $313
3,514
kWh
$26
5
kW-months/year
10: 2.7291 RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS Savings:
$188
Cost:
$1,500
$143 1,612 $45 8 $143
1,612
kWh
$45
8
kW-months/year
TOTAL RECOMMENDED Savings:
$67,910
Cost:
$138,665
$62,411 701,201 $5,499 1,019 $62,411
701,201
kWh
$5,499
1,019
kW-months/year
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand