Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Michigan State University |
---|---|
Assessment Year | 2025 |
Principal Product | Automotive Parts |
NAICS | 336320 - Motor Vehicle Electrical and Electronic Equipment Manufacturing |
SIC | 3714 - Motor Vehicle Parts And Accessories |
Sales | $50,000,000-$100,000,000 |
# of Employees | 144 |
Plant Area (Sq.Ft.) | 142,000 |
Annual Production | 464,000 Pieces |
Production Hrs. Annual | 6,240 |
Location (State) | MI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $176,443 | 2,762,272 | kWh | $0.06 |
Electricity Demand | $42,744 | 6,136 | kW-months/year | $6.97 |
Electricity Fees | $44,370 | - | $ | - |
Natural Gas | $70,223 | 7,118 | MMBtu | $9.87 |
Other Gas | $25,722 | 1 | MMBtu | $25,722.00 |
TOTAL ENERGY COSTS | $359,502 | |||
RECOMMENDED SAVINGS* | $79,415 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $21,227 Cost: - |
- | - | - | - | - | - | $21,227 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$21,227 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.425 ELIMINATE/REDUCE REDUNDANT INSPECTIONS |
Savings: $19,774 Cost: - |
$14,459 | 225,920 | $5,315 | 763 | - | - | - | - |
$14,459 225,920 kWh |
$5,315 763 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4227 USE COMPRESSOR AIR FILTERS |
Savings: $1,622 Cost: $5,814 |
$1,341 | 20,955 | $281 | 40 | - | - | - | - |
$1,341 20,955 kWh |
$281 40 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,999 Cost: - |
$1,652 | 25,819 | $346 | 50 | - | - | - | - |
$1,652 25,819 kWh |
$346 50 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $217 Cost: $80 |
$180 | 2,808 | $38 | 5 | - | - | - | - |
$180 2,808 kWh |
$38 5 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $12,629 Cost: $80,450 |
$10,443 | 163,179 | $2,186 | 314 | - | - | - | - |
$10,443 163,179 kWh |
$2,186 314 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $7,006 Cost: - |
$5,794 | 90,531 | $1,212 | 174 | - | - | - | - |
$5,794 90,531 kWh |
$1,212 174 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $685 Cost: - |
$543 | 8,487 | $142 | 20 | - | - | - | - |
$543 8,487 kWh |
$142 20 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $264 Cost: $138 |
$204 | 3,182 | $61 | 9 | - | - | - | - |
$204 3,182 kWh |
$61 9 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $5,080 Cost: - |
$936 | 14,630 | $437 | 63 | $3,707 | 375 | - | - |
$936 14,630 kWh |
$437 63 kW-months/year |
$3,707 375 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7231 USE RADIANT HEATER FOR SPOT HEATING |
Savings: $6,878 Cost: $14,109 |
- | - | - | - | $6,878 | 697 | - | - |
- - kWh |
- - kW-months/year |
$6,878 697 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $986 Cost: $836 |
$813 | 12,697 | $173 | 25 | - | - | - | - |
$813 12,697 kWh |
$173 25 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.7444 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS |
Savings: $659 Cost: $513 |
$38 | 589 | $8 | 1 | $613 | 62 | - | - |
$38 589 kWh |
$8 1 kW-months/year |
$613 62 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14: 4.821 PAY BILLS ON TIME TO AVOID LATE FEES |
Savings: $388 Cost: - |
- | - | - | - | - | - | $388 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$388 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $79,415 Cost: $101,940 |
$36,403 | 568,797 | $10,198 | 1,464 | $11,199 | 1,134 | $21,615 | - | $36,403 568,797 kWh |
$10,198 1,464 kW-months/year |
$11,199 1,134 MMBtu |
$21,615 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes |