IAC logo
IAC Assessment: MUCM08
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: MUCM08
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Michigan State University
Assessment Year 2022
Principal Product Education
NAICS 611110 - Elementary and Secondary Schools
SIC 8211 - Elementary And Secondary Schools
Sales <$500,000
# of Employees 80
Plant Area (Sq.Ft.) 62,075
Annual Production 1,500 Units
Production Hrs. Annual 1,995
Location (State) MI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $4,006 23,656 kWh $0.17
Natural Gas $2,060 218 MMBtu $9.45
TOTAL ENERGY COSTS $6,066
RECOMMENDED SAVINGS* $2,787 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $1,415
#|Description Savings
Cost
Status Electricity Usage Natural Gas Water Usage Electricity Usage Natural Gas Water Usage
$ kWh $ MMBtu $ Tgal
01: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS Savings:
$1,313
Cost:
$4,706
- - $1,313 139 - - -
-
kWh
$1,313
139
MMBtu
-
-
Tgal
02: 2.6232 INSTALL SET-BACK TIMERS Savings:
$792
Cost:
$428
$792 4,688 - - - - $792
4,688
kWh
-
-
MMBtu
-
-
Tgal
03: 3.4151 MINIMIZE WATER USAGE Savings:
$350
Cost:
$102
- - - - $350 58 -
-
kWh
-
-
MMBtu
$350
58
Tgal
04: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$272
Cost:
$1,280
$272 1,672 - - - - $272
1,672
kWh
-
-
MMBtu
-
-
Tgal
05: 2.1131 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC Savings:
$59
Cost:
$130
- - $59 6 - - -
-
kWh
$59
6
MMBtu
-
-
Tgal
TOTAL RECOMMENDED Savings:
$2,787
Cost:
$6,646
$1,065 6,359 $1,372 145 $350 58 $1,065
6,359
kWh
$1,372
145
MMBtu
$350
58
Tgal
TOTAL IMPLEMENTED Savings:
$1,415
Cost:
$1,810
$1,065 6,359 - - $350 58 $1,065
6,359
kWh
-
-
MMBtu
$350
58
Tgal
Savings
Cost
$ kWh $ MMBtu $ Tgal
Electricity Usage Natural Gas Water Usage Electricity Usage Natural Gas Water Usage