Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Missouri-Columbia
Assessment Year 2014
Principal Product cement
NAICS 327310 - Cement Manufacturing
SIC 3241 - Cement, Hydraulic
Sales $100,000,000-$500,000,000
# of Employees 105
Plant Area (Sq.Ft.) 2,000,000
Annual Production 2,100,000 Tons
Production Hrs. Annual 8,700
Location (State) MO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $8,011,619 221,935,612 kWh $0.04
Electricity Demand $4,662,123 402,323 kW-months/year $11.59
Natural Gas $334,000 85,000 MMBtu $3.93
Coal $8,000,000 5,003,800 MMBtu $1.60
Other Energy $260,000 9,466 MMBtu $27.47
TOTAL ENERGY COSTS $21,267,742
RECOMMENDED SAVINGS* $6,565,723 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Other Energy Personnel Changes Electricity Usage Electricity Demand Other Energy Personnel Changes
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.3412 USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR Savings:
$5,306,536
Cost:
$18,000,000
$3,664,980 101,523,000 $1,641,556 141,660 - - - - $3,664,980
101,523,000
kWh
$1,641,556
141,660
kW-months/year
-
-
MMBtu
-
-
$
02: 3.1161 ELIMINATE/REDUCE AN OPERATION Savings:
$218,015
Cost:
-
$150,573 4,171,000 $67,442 5,820 - - - - $150,573
4,171,000
kWh
$67,442
5,820
kW-months/year
-
-
MMBtu
-
-
$
03: 2.2511 INSULATE BARE EQUIPMENT Savings:
$66,528
Cost:
$339,300
$45,948 1,272,800 $20,580 1,776 - - - - $45,948
1,272,800
kWh
$20,580
1,776
kW-months/year
-
-
MMBtu
-
-
$
04: 4.445 INSTALL EQUIPMENT TO MOVE PRODUCT Savings:
$974,644
Cost:
$3,131,120
$(-70,771) (-1,960,488) $(-31,125) (-2,686) $230,736 8,560 $845,804 - $(-70,771)
(-1,960,488)
kWh
$(-31,125)
(-2,686)
kW-months/year
$230,736
8,560
MMBtu
$845,804
-
$
TOTAL RECOMMENDED Savings:
$6,565,723
Cost:
$21,470,420
$3,790,730 105,006,312 $1,698,453 146,570 $230,736 8,560 $845,804 - $3,790,730
105,006,312
kWh
$1,698,453
146,570
kW-months/year
$230,736
8,560
MMBtu
$845,804
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Other Energy Personnel Changes Electricity Usage Electricity Demand Other Energy Personnel Changes