Select a Center

Arizona State University
Boise State University
Case Western Reserve University
Clemson University
Colorado State University
Georgia Institute of Technology
Indiana University-Purdue University
Lehigh University
Louisiana State University
North Carolina State
Oklahoma State University
Oregon State University
San Diego State University
San Francisco State University
Syracuse University
Tennessee Technological University
Texas A&M, College Station
University of Alabama
University of Dayton
University of Delaware
University of Florida
University of Illinois, Chicago
University of Kentucky
University of Massachusetts
University of Miami
University of Missouri-Columbia
University of Nebraska–Lincoln
University of Texas Rio Grande Valley
University of Utah
University of Wisconsin, Milwaukee
West Virginia University
IAC logo
IAC Assessment: MZ0283
Sponsored by:
EERE AMO
IAC logo
IAC Assessment: MZ0283
Due to University and State restrictions, IAC assessment activities at your local center may be on hold.
Contact your local center for more details on operating status and available services.

Click here for details about Coronavirus (COVID-19) Recovery Support programs
IAC Center University of Missouri-Columbia
Assessment Year 2019
Principal Product treated mucicipal wastewater
NAICS 221320 - Sewage Treatment Facilities
SIC 4952 - Sewerage Systems
Sales $80,000
# of Employees 4
Plant Area (Sq.Ft.) 348,480
Annual Production 3,760 Units
Production Hrs. Annual 8,760
Location (State) MO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $240,765 3,238,700 kWh $0.07
Electricity Demand $21,980 5,941 kW/month $3.70
Natural Gas $15,440 1,982 MMBtu $7.79
TOTAL ENERGY COSTS $278,184
RECOMMENDED SAVINGS* $132,480 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand One-time Revenue or Avoided Cost Electricity Usage Electricity Demand One-time Revenue or Avoided Cost
$ kWh $ kW/month $ $
01: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$2,320
Cost:
$320
$2,172 29,354 $148 40 - - $2,172
29,354
kWh
$148
40
kW/month
-
-
$
02: 4.212 ADOPT IN-HOUSE MATERIAL GENERATION Savings:
$14,280
Cost:
$43,150
- - - - $14,280 - -
-
kWh
-
-
kW/month
$14,280
-
$
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$36
Cost:
$20
$34 456 $2 1 - - $34
456
kWh
$2
1
kW/month
-
-
$
04: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$221
Cost:
$1,096
$221 2,983 - - - - $221
2,983
kWh
-
-
kW/month
-
-
$
05: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL Savings:
$74,880
Cost:
-
- - - - $74,880 - -
-
kWh
-
-
kW/month
$74,880
-
$
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$40,743
Cost:
$12,366
$35,834 484,241 $4,909 1,327 - - $35,834
484,241
kWh
$4,909
1,327
kW/month
-
-
$
TOTAL RECOMMENDED Savings:
$132,480
Cost:
$56,952
$38,261 517,034 $5,059 1,368 $89,160 - $38,261
517,034
kWh
$5,059
1,368
kW/month
$89,160
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW/month
-
-
$
Savings
Cost
$ kWh $ kW/month $ $
Electricity Usage Electricity Demand One-time Revenue or Avoided Cost Electricity Usage Electricity Demand One-time Revenue or Avoided Cost