Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Missouri-Columbia
Assessment Year 2022
Principal Product pontoon boats
NAICS 336612 - Boat Building
SIC 3999 - Manufacturing Industries, Nec
Sales $100,000,000-$500,000,000
# of Employees 500
Plant Area (Sq.Ft.) 236,000
Annual Production 14,000 Pieces
Production Hrs. Annual 5,000
Location (State) MO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $190,987 2,430,967 kWh $0.08
Electricity Demand $42,724 7,212 kW-months/year $5.92
LPG $84,777 4,409 MMBtu $19.23
TOTAL ENERGY COSTS $318,488
RECOMMENDED SAVINGS* $141,914 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $57,839
#|Description Savings
Cost
Status Electricity Usage Electricity Demand LPG Electricity Usage Electricity Demand LPG
$ kWh $ kW-months/year $ MMBtu
01: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$299
Cost:
$960
$299 3,790 - - - - $299
3,790
kWh
-
-
kW-months/year
-
-
MMBtu
02: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS Savings:
$31,637
Cost:
$25,442
$(-578) (-7,318) $(-244) (-41) $32,459 1,688 $(-578)
(-7,318)
kWh
$(-244)
(-41)
kW-months/year
$32,459
1,688
MMBtu
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$13,649
Cost:
$16,300
- - - - $13,649 710 -
-
kWh
-
-
kW-months/year
$13,649
710
MMBtu
04: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$61,626
Cost:
$574,750
$61,626 780,077 - - - - $61,626
780,077
kWh
-
-
kW-months/year
-
-
MMBtu
05: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$3,801
Cost:
$6,385
$3,222 40,786 $579 98 - - $3,222
40,786
kWh
$579
98
kW-months/year
-
-
MMBtu
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$25,903
Cost:
$17,890
$25,903 327,926 - - - - $25,903
327,926
kWh
-
-
kW-months/year
-
-
MMBtu
07: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$4,999
Cost:
$25,044
$4,237 53,640 $762 129 - - $4,237
53,640
kWh
$762
129
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$141,914
Cost:
$666,771
$94,709 1,198,901 $1,097 186 $46,108 2,398 $94,709
1,198,901
kWh
$1,097
186
kW-months/year
$46,108
2,398
MMBtu
TOTAL IMPLEMENTED Savings:
$57,839
Cost:
$44,292
$25,624 324,398 $(-244) (-41) $32,459 1,688 $25,624
324,398
kWh
$(-244)
(-41)
kW-months/year
$32,459
1,688
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand LPG Electricity Usage Electricity Demand LPG