Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Missouri-Columbia
Assessment Year 2024
Principal Product metal cans
NAICS 332431 - Metal Can Manufacturing
SIC 3411 - Metal Cans
Sales $100,000,000-$500,000,000
# of Employees 112
Plant Area (Sq.Ft.) 414,000
Annual Production 1,231,711,104 Pieces
Production Hrs. Annual 4,368
Location (State) IA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $1,232,879 31,813,600 kWh $0.04
Electricity Demand $1,206,380 52,999 kW-months/year $22.76
Natural Gas $742,452 322,266 MMBtu $2.30
TOTAL ENERGY COSTS $3,431,146
RECOMMENDED SAVINGS* $193,490 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Water Usage Water Disposal Electricity Usage Electricity Demand Water Usage Water Disposal
$ kWh $ kW-months/year $ Tgal $ Tgal
01: 3.4159 REPLACE TREATED WATER WITH WELL / SURFACE WATER Savings:
$21,410
Cost:
$168,000
- - - - $11,785 5,333 $9,625 2,667 -
-
kWh
-
-
kW-months/year
$11,785
5,333
Tgal
$9,625
2,667
Tgal
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$9,395
Cost:
$800
$3,609 92,542 $5,786 254 - - - - $3,609
92,542
kWh
$5,786
254
kW-months/year
-
-
Tgal
-
-
Tgal
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$3,674
Cost:
$14,000
$3,674 94,198 - - - - - - $3,674
94,198
kWh
-
-
kW-months/year
-
-
Tgal
-
-
Tgal
04: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL Savings:
$11,668
Cost:
$59,968
$3,884 99,591 $7,784 342 - - - - $3,884
99,591
kWh
$7,784
342
kW-months/year
-
-
Tgal
-
-
Tgal
05: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$147,343
Cost:
$2,297,063
$147,343 3,778,038 - - - - - - $147,343
3,778,038
kWh
-
-
kW-months/year
-
-
Tgal
-
-
Tgal
TOTAL RECOMMENDED Savings:
$193,490
Cost:
$2,539,831
$158,510 4,064,369 $13,570 596 $11,785 5,333 $9,625 2,667 $158,510
4,064,369
kWh
$13,570
596
kW-months/year
$11,785
5,333
Tgal
$9,625
2,667
Tgal
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
Tgal
-
-
Tgal
Savings
Cost
$ kWh $ kW-months/year $ Tgal $ Tgal
Electricity Usage Electricity Demand Water Usage Water Disposal Electricity Usage Electricity Demand Water Usage Water Disposal