Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Nebraska–Lincoln |
---|---|
Assessment Year | 2017 |
Principal Product | power distribution units |
NAICS | 335999 - All Other Miscellaneous Electrical Equipment and Component Manufacturing |
SIC | 3699 - Electrical Equipment & Supplies, Nec |
Sales | $50,000,000-$100,000,000 |
# of Employees | 140 |
Plant Area (Sq.Ft.) | 77,000 |
Annual Production | 3,000,000 Units |
Production Hrs. Annual | 2,500 |
Location (State) | NE |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $37,546 | 1,291,500 | kWh | $0.03 |
Electricity Demand | $71,758 | 4,797 | kW-months/year | $14.96 |
Natural Gas | $24,758 | 9,634 | MMBtu | $2.57 |
TOTAL ENERGY COSTS | $136,587 | |||
RECOMMENDED SAVINGS* | $7,343 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $1,797 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Increase in Production | Electricity Usage | Electricity Demand | Natural Gas | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $3,412 Cost: $15,000 |
- | - | - | - | $300 | 117 | $3,112 | - |
- - kWh |
- - kW-months/year |
$300 117 MMBtu |
$3,112 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2522 ISOLATE HOT OR COLD EQUIPMENT |
Savings: $1,797 Cost: $14,000 |
$278 | 9,600 | $1,519 | 102 | - | - | - | - |
$278 9,600 kWh |
$1,519 102 kW-months/year |
- - MMBtu |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7446 UTILIZE SENSORS CONTROLLING ROOF AND WALL OPENINGS |
Savings: $1,586 Cost: $4,300 |
$122 | 4,200 | $950 | 64 | $514 | 200 | - | - |
$122 4,200 kWh |
$950 64 kW-months/year |
$514 200 MMBtu |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $348 Cost: $1,250 |
$348 | 11,800 | - | - | - | - | - | - |
$348 11,800 kWh |
- - kW-months/year |
- - MMBtu |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $200 Cost: $250 |
$200 | 6,896 | - | - | - | - | - | - |
$200 6,896 kWh |
- - kW-months/year |
- - MMBtu |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $7,343 Cost: $34,800 |
$948 | 32,496 | $2,469 | 166 | $814 | 317 | $3,112 | - | $948 32,496 kWh |
$2,469 166 kW-months/year |
$814 317 MMBtu |
$3,112 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $1,797 Cost: $14,000 |
$278 | 9,600 | $1,519 | 102 | - | - | - | - | $278 9,600 kWh |
$1,519 102 kW-months/year |
- - MMBtu |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Increase in Production | Electricity Usage | Electricity Demand | Natural Gas | Increase in Production |