IAC logo
IAC Assessment: NL0003
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: NL0003
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Nebraska–Lincoln
Assessment Year 2017
Principal Product power distribution units
NAICS 335999 - All Other Miscellaneous Electrical Equipment and Component Manufacturing
SIC 3699 - Electrical Equipment & Supplies, Nec
Sales $50,000,000-$100,000,000
# of Employees 140
Plant Area (Sq.Ft.) 77,000
Annual Production 3,000,000 Units
Production Hrs. Annual 2,500
Location (State) NE
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $37,546 1,291,500 kWh $0.03
Electricity Demand $71,758 4,797 kW-months/year $14.96
Natural Gas $24,758 9,634 MMBtu $2.57
TOTAL ENERGY COSTS $136,587
RECOMMENDED SAVINGS* $7,343 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $1,797
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Increase in Production Electricity Usage Electricity Demand Natural Gas Increase in Production
$ kWh $ kW-months/year $ MMBtu $ %
01: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$3,412
Cost:
$15,000
- - - - $300 117 $3,112 - -
-
kWh
-
-
kW-months/year
$300
117
MMBtu
$3,112
-
%
02: 2.2522 ISOLATE HOT OR COLD EQUIPMENT Savings:
$1,797
Cost:
$14,000
$278 9,600 $1,519 102 - - - - $278
9,600
kWh
$1,519
102
kW-months/year
-
-
MMBtu
-
-
%
03: 2.7446 UTILIZE SENSORS CONTROLLING ROOF AND WALL OPENINGS Savings:
$1,586
Cost:
$4,300
$122 4,200 $950 64 $514 200 - - $122
4,200
kWh
$950
64
kW-months/year
$514
200
MMBtu
-
-
%
04: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$348
Cost:
$1,250
$348 11,800 - - - - - - $348
11,800
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
%
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$200
Cost:
$250
$200 6,896 - - - - - - $200
6,896
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
%
TOTAL RECOMMENDED Savings:
$7,343
Cost:
$34,800
$948 32,496 $2,469 166 $814 317 $3,112 - $948
32,496
kWh
$2,469
166
kW-months/year
$814
317
MMBtu
$3,112
-
%
TOTAL IMPLEMENTED Savings:
$1,797
Cost:
$14,000
$278 9,600 $1,519 102 - - - - $278
9,600
kWh
$1,519
102
kW-months/year
-
-
MMBtu
-
-
%
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ %
Electricity Usage Electricity Demand Natural Gas Increase in Production Electricity Usage Electricity Demand Natural Gas Increase in Production