Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Nebraska–Lincoln |
---|---|
Assessment Year | 2023 |
Principal Product | Cheese |
NAICS | 311513 - Cheese Manufacturing |
SIC | 2022 - Cheese, Natural And Processed |
Sales | $100,000,000-$500,000,000 |
# of Employees | 175 |
Plant Area (Sq.Ft.) | 130,000 |
Annual Production | 81,000,000 Pounds |
Production Hrs. Annual | 8,760 |
Location (State) | MN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $692,689 | 12,369,450 | kWh | $0.06 |
Electricity Demand | $379,863 | 22,227 | kW-months/year | $17.09 |
Electricity Fees | $344,077 | - | $ | - |
Natural Gas | $1,792,892 | 234,059 | MMBtu | $7.66 |
TOTAL ENERGY COSTS | $3,209,521 | |||
RECOMMENDED SAVINGS* | $809,266 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3415 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT |
Savings: $491,419 Cost: $1,990,800 |
$1,240,310 | 9,986,400 | - | - | $(-748,891) | (-56,844) | - | - | - | - | - | - |
$1,240,310 9,986,400 kWh |
- - kW-months/year |
$(-748,891) (-56,844) MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $254,315 Cost: $454,461 |
- | - | - | - | $254,315 | 33,196 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$254,315 33,196 MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2113 REPAIR OR REPLACE STEAM TRAPS |
Savings: $17,666 Cost: $50 |
- | - | - | - | $19,316 | 2,522 | - | - | $(-1,650) | - | - | - |
- - kWh |
- - kW-months/year |
$19,316 2,522 MMBtu |
- - lb |
$(-1,650) - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2696 USE EXCESS COLD PROCESS FLUID FOR INDUSTRIAL COOLING NEEDS |
Savings: $12,625 Cost: $8,000 |
$274 | 4,897 | $12,351 | 723 | - | - | - | - | - | - | - | - |
$274 4,897 kWh |
$12,351 723 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1243 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER |
Savings: $11,616 Cost: $7,640 |
- | - | - | - | $11,616 | 1,517 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$11,616 1,517 MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.5311 RECOVER AND REUSE WASTE MATERIAL |
Savings: $10,817 Cost: $3,660 |
- | - | - | - | - | - | $9,900 | 55,000 | $917 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$9,900 55,000 lb |
$917 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $9,789 Cost: $100 |
$10,489 | 187,308 | - | - | - | - | - | - | $(-600) | - | $(-100) | - |
$10,489 187,308 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$(-600) - $ |
$(-100) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,019 Cost: $768 |
$718 | 12,827 | $301 | 18 | - | - | - | - | - | - | - | - |
$718 12,827 kWh |
$301 18 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $809,266 Cost: $2,465,479 |
$1,251,791 | 10,191,432 | $12,652 | 740 | $(-463,644) | (-19,609) | $9,900 | 55,000 | $(-1,333) | - | $(-100) | - | $1,251,791 10,191,432 kWh |
$12,652 740 kW-months/year |
$(-463,644) (-19,609) MMBtu |
$9,900 55,000 lb |
$(-1,333) - $ |
$(-100) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Ancillary Material Cost |