Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Nevada
Assessment Year 1996
Principal Product Monorail Train System
NAICS n/a
SIC 3743 - Railroad Equipment
Sales $10,000,000-$50,000,000
# of Employees 60
Plant Area (Sq.Ft.) 52,100
Annual Production 1,500 Units
Production Hrs. Annual 2,080
Location (State) NV
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $36,058 787,515 kWh $0.05
Electricity Demand $33,631 3,624 kW-months/year $9.28
Electricity Fees $1,623 - $ -
Natural Gas $17,884 3,557 MMBtu $5.03
TOTAL ENERGY COSTS $89,596
RECOMMENDED SAVINGS* $6,097 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $1,155
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Solid Waste (non-haz) Electricity Usage Electricity Demand Natural Gas Solid Waste (non-haz)
$ kWh $ kW-months/year $ MMBtu $ lb
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,155
Cost:
$600
$1,155 25,205 - - - - - - $1,155
25,205
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
lb
02: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$2,773
Cost:
$425
$1,279 27,843 $1,494 161 - - - - $1,279
27,843
kWh
$1,494
161
kW-months/year
-
-
MMBtu
-
-
lb
03: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$617
Cost:
$227
$241 5,275 $376 41 - - - - $241
5,275
kWh
$376
41
kW-months/year
-
-
MMBtu
-
-
lb
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$307
Cost:
$300
$307 6,741 - - - - - - $307
6,741
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
lb
05: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS Savings:
$845
Cost:
$1,625
- - - - $845 177 - - -
-
kWh
-
-
kW-months/year
$845
177
MMBtu
-
-
lb
06: 3.5248 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE Savings:
$400
Cost:
-
- - - - - - $400 10,000 -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$400
10,000
lb
TOTAL RECOMMENDED Savings:
$6,097
Cost:
$3,177
$2,982 65,064 $1,870 202 $845 177 $400 10,000 $2,982
65,064
kWh
$1,870
202
kW-months/year
$845
177
MMBtu
$400
10,000
lb
TOTAL IMPLEMENTED Savings:
$1,155
Cost:
$600
$1,155 25,205 - - - - - - $1,155
25,205
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
lb
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ lb
Electricity Usage Electricity Demand Natural Gas Solid Waste (non-haz) Electricity Usage Electricity Demand Natural Gas Solid Waste (non-haz)