Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Nevada |
---|---|
Assessment Year | 1997 |
Principal Product | Pressure treated wood products |
NAICS | n/a |
SIC | 2491 - Wood Preserving |
Sales | $1,000,000-$5,000,000 |
# of Employees | 26 |
Plant Area (Sq.Ft.) | 350,000 |
Annual Production | 1,500,000 Units |
Production Hrs. Annual | 8,760 |
Location (State) | NV |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $29,012 | 623,388 | kWh | $0.05 |
Electricity Demand | $15,516 | 1,687 | kW-months/year | $9.20 |
Electricity Fees | $1,349 | - | $ | - |
Natural Gas | $88,638 | 16,938 | MMBtu | $5.23 |
TOTAL ENERGY COSTS | $134,515 | |||
RECOMMENDED SAVINGS* | $31,508 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $1,533 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $8,890 Cost: $9,124 |
- | - | - | - | $8,890 | 1,733 | - | - | - | - |
- - kWh |
- - kW-months/year |
$8,890 1,733 MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $13,870 Cost: $7,320 |
- | - | - | - | $13,870 | 2,766 | - | - | - | - |
- - kWh |
- - kW-months/year |
$13,870 2,766 MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS |
Savings: $1,071 Cost: $250 |
- | - | - | - | $1,071 | 214 | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,071 214 MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $325 Cost: $409 |
- | - | - | - | $325 | 65 | - | - | - | - |
- - kWh |
- - kW-months/year |
$325 65 MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $896 Cost: $196 |
$737 | 15,826 | $159 | 17 | - | - | - | - | - | - |
$737 15,826 kWh |
$159 17 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $3,129 Cost: $3,350 |
- | - | - | - | $3,129 | 624 | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,129 624 MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $137 Cost: $10 |
$137 | 2,931 | - | - | - | - | - | - | - | - |
$137 2,931 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.3128 UTILIZE OTHER METHODS TO REMOVE CONTAMINANTS |
Savings: $840 Cost: $408 |
- | - | - | - | - | - | $840 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$840 - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.821 PAY BILLS ON TIME TO AVOID LATE FEES |
Savings: $2,350 Cost: - |
- | - | - | - | - | - | - | - | $2,350 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$2,350 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $31,508 Cost: $21,067 |
$874 | 18,757 | $159 | 17 | $27,285 | 5,402 | $840 | - | $2,350 | - | $874 18,757 kWh |
$159 17 kW-months/year |
$27,285 5,402 MMBtu |
$840 - lb |
$2,350 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $1,533 Cost: $669 |
$137 | 2,931 | - | - | $1,396 | 279 | - | - | - | - | $137 2,931 kWh |
- - kW-months/year |
$1,396 279 MMBtu |