Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Nevada |
---|---|
Assessment Year | 1997 |
Principal Product | Aftermarket and OEM vehicle fuel tanks |
NAICS | n/a |
SIC | 3417 - |
Sales | $1,000,000-$5,000,000 |
# of Employees | 37 |
Plant Area (Sq.Ft.) | 30,000 |
Annual Production | 1,090,000 Pounds |
Production Hrs. Annual | 2,210 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $25,091 | 297,773 | kWh | $0.08 |
Electricity Demand | $5,238 | 1,387 | kW-months/year | $3.78 |
Electricity Fees | $2,522 | - | $ | - |
Natural Gas | $7,762 | 1,331 | MMBtu | $5.83 |
TOTAL ENERGY COSTS | $40,613 | |||
RECOMMENDED SAVINGS* | $19,489 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $18,761 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2525 ELIMINATE COOLING OF PROCESS STREAMS WHICH SUBSEQUENTLY MUST BE HEATED AND VICE VERSA |
Savings: $1,252 Cost: $200 |
- | - | - | - | $1,252 | 226 | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,252 226 MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $728 Cost: $50 |
$608 | 7,327 | $120 | 32 | - | - | - | - | - | - |
$608 7,327 kWh |
$120 32 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $1,478 Cost: $125 |
$762 | 9,086 | $716 | 190 | - | - | - | - | - | - |
$762 9,086 kWh |
$716 190 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1135 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY |
Savings: $729 Cost: $100 |
- | - | - | - | $729 | 131 | - | - | - | - |
- - kWh |
- - kW-months/year |
$729 131 MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.5248 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE |
Savings: $336 Cost: $100 |
- | - | - | - | - | - | $336 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$336 - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.425 ELIMINATE/REDUCE REDUNDANT INSPECTIONS |
Savings: $14,966 Cost: $7,500 |
- | - | - | - | - | - | - | - | $14,966 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$14,966 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $19,489 Cost: $8,075 |
$1,370 | 16,413 | $836 | 222 | $1,981 | 357 | $336 | - | $14,966 | - | $1,370 16,413 kWh |
$836 222 kW-months/year |
$1,981 357 MMBtu |
$336 - lb |
$14,966 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $18,761 Cost: $8,025 |
$762 | 9,086 | $716 | 190 | $1,981 | 357 | $336 | - | $14,966 | - | $762 9,086 kWh |
$716 190 kW-months/year |
$1,981 357 MMBtu |
$336 - lb |
$14,966 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes |