Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Nevada |
---|---|
Assessment Year | 1998 |
Principal Product | Lightning Protection Equipment |
NAICS | n/a |
SIC | 3643 - Current-carrying Wiring Devices |
Sales | $10,000,000-$50,000,000 |
# of Employees | 150 |
Plant Area (Sq.Ft.) | 53,000 |
Annual Production | 500,000 Pieces |
Production Hrs. Annual | 4,080 |
Location (State) | NV |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $14,017 | 335,873 | kWh | $0.04 |
Electricity Demand | $11,470 | 1,236 | kW-months/year | $9.28 |
Electricity Fees | $600 | - | $ | - |
Natural Gas | $4,706 | 715 | MMBtu | $6.58 |
TOTAL ENERGY COSTS | $40,687 | |||
RECOMMENDED SAVINGS* | $69,600 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $69,567 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Primary Product | By-product Production | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Primary Product | By-product Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $179 Cost: $137 |
$108 | 2,638 | $71 | 8 | - | - | - | - | - | - | - | - |
$108 2,638 kWh |
$71 8 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $550 Cost: $200 |
$238 | 5,569 | $312 | 34 | - | - | - | - | - | - | - | - |
$238 5,569 kWh |
$312 34 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $912 Cost: $750 |
- | - | - | - | $912 | 139 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$912 139 MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES |
Savings: $44,986 Cost: $9,960 |
- | - | - | - | - | - | - | - | - | - | $44,986 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
$44,986 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.114 ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS |
Savings: $22,940 Cost: $7,800 |
- | - | - | - | - | - | - | - | $22,940 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$22,940 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.5212 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS |
Savings: $33 Cost: - |
- | - | - | - | - | - | $33 | 535 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$33 535 lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $69,600 Cost: $18,847 |
$346 | 8,207 | $383 | 42 | $912 | 139 | $33 | 535 | $22,940 | - | $44,986 | - | $346 8,207 kWh |
$383 42 kW-months/year |
$912 139 MMBtu |
$33 535 lb |
$22,940 - $ |
$44,986 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $69,567 Cost: $18,847 |
$346 | 8,207 | $383 | 42 | $912 | 139 | - | - | $22,940 | - | $44,986 | - | $346 8,207 kWh |
$383 42 kW-months/year |
$912 139 MMBtu |
- - lb |
$22,940 - $ |
$44,986 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Primary Product | By-product Production | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Primary Product | By-product Production |