Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Nevada
Assessment Year 1998
Principal Product Lightning Protection Equipment
NAICS n/a
SIC 3643 - Current-carrying Wiring Devices
Sales $10,000,000-$50,000,000
# of Employees 150
Plant Area (Sq.Ft.) 53,000
Annual Production 500,000 Pieces
Production Hrs. Annual 4,080
Location (State) NV
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $14,017 335,873 kWh $0.04
Electricity Demand $11,470 1,236 kW-months/year $9.28
Electricity Fees $600 - $ -
Natural Gas $4,706 715 MMBtu $6.58
TOTAL ENERGY COSTS $40,687
RECOMMENDED SAVINGS* $69,600 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $69,567
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Solid Waste (non-haz) Primary Product By-product Production Electricity Usage Electricity Demand Natural Gas Solid Waste (non-haz) Primary Product By-product Production
$ kWh $ kW-months/year $ MMBtu $ lb $ $ $ $
01: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$179
Cost:
$137
$108 2,638 $71 8 - - - - - - - - $108
2,638
kWh
$71
8
kW-months/year
-
-
MMBtu
-
-
lb
-
-
$
-
-
$
02: 2.7134 USE PHOTOCELL CONTROLS Savings:
$550
Cost:
$200
$238 5,569 $312 34 - - - - - - - - $238
5,569
kWh
$312
34
kW-months/year
-
-
MMBtu
-
-
lb
-
-
$
-
-
$
03: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS Savings:
$912
Cost:
$750
- - - - $912 139 - - - - - - -
-
kWh
-
-
kW-months/year
$912
139
MMBtu
-
-
lb
-
-
$
-
-
$
04: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES Savings:
$44,986
Cost:
$9,960
- - - - - - - - - - $44,986 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
lb
-
-
$
$44,986
-
$
05: 4.114 ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS Savings:
$22,940
Cost:
$7,800
- - - - - - - - $22,940 - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
lb
$22,940
-
$
-
-
$
06: 3.5212 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS Savings:
$33
Cost:
-
- - - - - - $33 535 - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$33
535
lb
-
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$69,600
Cost:
$18,847
$346 8,207 $383 42 $912 139 $33 535 $22,940 - $44,986 - $346
8,207
kWh
$383
42
kW-months/year
$912
139
MMBtu
$33
535
lb
$22,940
-
$
$44,986
-
$
TOTAL IMPLEMENTED Savings:
$69,567
Cost:
$18,847
$346 8,207 $383 42 $912 139 - - $22,940 - $44,986 - $346
8,207
kWh
$383
42
kW-months/year
$912
139
MMBtu
-
-
lb
$22,940
-
$
$44,986
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ lb $ $ $ $
Electricity Usage Electricity Demand Natural Gas Solid Waste (non-haz) Primary Product By-product Production Electricity Usage Electricity Demand Natural Gas Solid Waste (non-haz) Primary Product By-product Production