IAC logo
IAC Assessment: OK0218
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: OK0218
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 1987
Principal Product GALV. STEEL PRODUCTS
NAICS n/a
SIC 3479 - Metal Coating And Allied Services
Sales $5,000,000-$10,000,000
# of Employees 125
Plant Area (Sq.Ft.) 0
Annual Production 72,000,000 Pounds
Production Hrs. Annual 6,240
Location (State) OK
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $21,776 398,007 kWh $0.05
Natural Gas $338,627 94,626 MMBtu $3.58
TOTAL ENERGY COSTS $360,403
RECOMMENDED SAVINGS* $40,290 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $6,140
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$291
Cost:
$255
$291 9,379 - - - - $291
9,379
kWh
-
-
MMBtu
-
-
$
02: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$3,933
Cost:
$1,500
- - $4,053 1,132 $(-120) - -
-
kWh
$4,053
1,132
MMBtu
$(-120)
-
$
03: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$1,296
Cost:
$965
- - $1,296 362 - - -
-
kWh
$1,296
362
MMBtu
-
-
$
04: 2.2514 COVER OPEN TANKS Savings:
$7,769
Cost:
$3,608
- - $7,769 2,170 - - -
-
kWh
$7,769
2,170
MMBtu
-
-
$
05: 2.1131 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC Savings:
$780
Cost:
$465
- - $780 218 - - -
-
kWh
$780
218
MMBtu
-
-
$
06: 2.1131 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC Savings:
$1,136
Cost:
$503
- - $1,136 317 - - -
-
kWh
$1,136
317
MMBtu
-
-
$
07: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$25,085
Cost:
$52,000
- - $25,085 7,007 - - -
-
kWh
$25,085
7,007
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$40,290
Cost:
$59,296
$291 9,379 $40,119 11,206 $(-120) - $291
9,379
kWh
$40,119
11,206
MMBtu
$(-120)
-
$
TOTAL IMPLEMENTED Savings:
$6,140
Cost:
$2,723
$291 9,379 $5,969 1,667 $(-120) - $291
9,379
kWh
$5,969
1,667
MMBtu
$(-120)
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes