IAC logo
IAC Assessment: OK0378
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: OK0378
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 1992
Principal Product PACKAGED JUICE PRODUCTS
NAICS n/a
SIC 2033 - Canned Fruits And Vegetables
Sales $10,000,000-$50,000,000
# of Employees 400
Plant Area (Sq.Ft.) 0
Annual Production 16,800,000 Pieces
Production Hrs. Annual 6,000
Location (State) OK
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $376,228 6,973,623 kWh $0.05
Natural Gas $216,874 90,121 MMBtu $2.41
TOTAL ENERGY COSTS $593,102
RECOMMENDED SAVINGS* $41,072 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $18,370
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$11,528
Cost:
$700
$10,793 192,263 - - $735 - $10,793
192,263
kWh
-
-
MMBtu
$735
-
$
02: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$7,435
Cost:
$3,500
- - $7,435 3,600 - - -
-
kWh
$7,435
3,600
MMBtu
-
-
$
03: 2.2447 HEAT WATER WITH EXHAUST HEAT Savings:
$8,382
Cost:
$270
- - $2,127 1,030 $6,255 - -
-
kWh
$2,127
1,030
MMBtu
$6,255
-
$
04: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$5,156
Cost:
$3,125
- - $5,156 2,497 - - -
-
kWh
$5,156
2,497
MMBtu
-
-
$
05: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$2,553
Cost:
$2,183
- - $2,553 1,235 - - -
-
kWh
$2,553
1,235
MMBtu
-
-
$
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$70
Cost:
-
$70 1,172 - - - - $70
1,172
kWh
-
-
MMBtu
-
-
$
07: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$5,948
Cost:
$8,560
$5,948 146,835 - - - - $5,948
146,835
kWh
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$41,072
Cost:
$18,338
$16,811 340,270 $17,271 8,362 $6,990 - $16,811
340,270
kWh
$17,271
8,362
MMBtu
$6,990
-
$
TOTAL IMPLEMENTED Savings:
$18,370
Cost:
$5,953
- - $12,115 5,865 $6,255 - -
-
kWh
$12,115
5,865
MMBtu
$6,255
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes