Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oklahoma State University |
---|---|
Assessment Year | 1996 |
Principal Product | Auto shock absorbers and struts |
NAICS | n/a |
SIC | 3714 - Motor Vehicle Parts And Accessories |
Sales | $100,000,000-$500,000,000 |
# of Employees | 750 |
Plant Area (Sq.Ft.) | 32,000,000 |
Annual Production | 15,600,000 Pieces |
Production Hrs. Annual | 5,200 |
Location (State) | OK |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $401,738 | 16,386,577 | kWh | $0.02 |
Electricity Demand | $221,601 | 31,116 | kW-months/year | $7.12 |
Electricity Fees | $54,204 | - | $ | - |
Natural Gas | $156,231 | 136,445 | MMBtu | $1.15 |
TOTAL ENERGY COSTS | $1,046,809 | |||
RECOMMENDED SAVINGS* | $33,997 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $7,580 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $4,955 Cost: $5,951 |
$4,955 | 186,401 | - | 36 | - | - | - | - |
$4,955 186,401 kWh |
- 36 kW-months/year |
- - MMBtu |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $5,401 Cost: $3,275 |
$3,333 | 125,440 | $2,068 | 288 | - | - | - | - |
$3,333 125,440 kWh |
$2,068 288 kW-months/year |
- - MMBtu |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4312 IMPROVE LUBRICATION PRACTICES |
Savings: $4,213 Cost: - |
$2,600 | 97,890 | $1,613 | 228 | - | - | - | - |
$2,600 97,890 kWh |
$1,613 228 kW-months/year |
- - MMBtu |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $1,548 Cost: $5,600 |
$1,548 | 58,324 | - | 112 | - | - | - | - |
$1,548 58,324 kWh |
- 112 kW-months/year |
- - MMBtu |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7122 DISCONNECT BALLASTS |
Savings: $428 Cost: $1,060 |
$264 | 9,965 | $164 | 24 | - | - | - | - |
$264 9,965 kWh |
$164 24 kW-months/year |
- - MMBtu |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $203 Cost: $757 |
- | - | - | - | $203 | 177 | - | - |
- - kWh |
- - kW-months/year |
$203 177 MMBtu |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.4113 TREAT AND REUSE RINSE WATERS |
Savings: $17,249 Cost: - |
- | - | - | - | - | - | $17,249 | 4,400 |
- - kWh |
- - kW-months/year |
- - MMBtu |
$17,249 4,400 gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $33,997 Cost: $16,643 |
$12,700 | 478,020 | $3,845 | 688 | $203 | 177 | $17,249 | 4,400 | $12,700 478,020 kWh |
$3,845 688 kW-months/year |
$203 177 MMBtu |
$17,249 4,400 gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $7,580 Cost: $10,692 |
$5,145 | 193,729 | $2,232 | 424 | $203 | 177 | - | - | $5,145 193,729 kWh |
$2,232 424 kW-months/year |
$203 177 MMBtu |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) |