IAC logo
IAC Assessment: OK0553
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: OK0553
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 1998
Principal Product Marine Propulsion Systems
NAICS n/a
SIC 3732 - Boat Building And Repairing
Sales $100,000,000-$500,000,000
# of Employees 1,100
Plant Area (Sq.Ft.) 300,000
Annual Production 93,000 Units
Production Hrs. Annual 6,240
Location (State) OK
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $1,150,540 41,006,155 kWh $0.03
Electricity Demand $728,426 - kW-months/year -
Natural Gas $528,547 168,108 MMBtu $3.14
TOTAL ENERGY COSTS $2,583,307
RECOMMENDED SAVINGS* $1,627,161 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $83,828
#|Description Savings
Cost
Status Electricity Usage Natural Gas Solid Waste (non-haz) Administrative Changes Ancillary Material Cost Electricity Usage Natural Gas Solid Waste (non-haz) Administrative Changes Ancillary Material Cost
$ kWh $ MMBtu $ lb $ $ $ $
01: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT Savings:
$69,793
Cost:
$76,000
$69,793 2,865,182 - - - - - - - - $69,793
2,865,182
kWh
-
-
MMBtu
-
-
lb
-
-
$
-
-
$
02: 2.2442 PREHEAT COMBUSTION AIR WITH WASTE HEAT Savings:
$19,308
Cost:
$57,400
- - $19,308 7,773 - - - - - - -
-
kWh
$19,308
7,773
MMBtu
-
-
lb
-
-
$
-
-
$
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$14,035
Cost:
$6,760
$14,035 579,426 - - - - - - - - $14,035
579,426
kWh
-
-
MMBtu
-
-
lb
-
-
$
-
-
$
04: 2.2514 COVER OPEN TANKS Savings:
$12,366
Cost:
$7,500
- - $12,366 1,732 - - - - - - -
-
kWh
$12,366
1,732
MMBtu
-
-
lb
-
-
$
-
-
$
05: 4.2110 CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE Savings:
$1,200,000
Cost:
-
- - - - - - - - $1,200,000 - -
-
kWh
-
-
MMBtu
-
-
lb
-
-
$
$1,200,000
-
$
06: 4.3210 OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES Savings:
$200,000
Cost:
-
- - - - - - $200,000 - - - -
-
kWh
-
-
MMBtu
-
-
lb
$200,000
-
$
-
-
$
07: 4.2110 CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE Savings:
$36,659
Cost:
$100,000
- - - - - - - - $36,659 - -
-
kWh
-
-
MMBtu
-
-
lb
-
-
$
$36,659
-
$
08: 3.5316 CONTRACT A WOOD PALLET RECYCLING COMPANY Savings:
$75,000
Cost:
-
- - - - $75,000 - - - - - -
-
kWh
-
-
MMBtu
$75,000
-
lb
-
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$1,627,161
Cost:
$247,660
$83,828 3,444,608 $31,674 9,505 $75,000 - $200,000 - $1,236,659 - $83,828
3,444,608
kWh
$31,674
9,505
MMBtu
$75,000
-
lb
$200,000
-
$
$1,236,659
-
$
TOTAL IMPLEMENTED Savings:
$83,828
Cost:
$82,760
$83,828 3,444,608 - - - - - - - - $83,828
3,444,608
kWh
-
-
MMBtu
-
-
lb
-
-
$
-
-
$
Savings
Cost
$ kWh $ MMBtu $ lb $ $ $ $
Electricity Usage Natural Gas Solid Waste (non-haz) Administrative Changes Ancillary Material Cost Electricity Usage Natural Gas Solid Waste (non-haz) Administrative Changes Ancillary Material Cost