Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oklahoma State University |
---|---|
Assessment Year | 1998 |
Principal Product | Marine Propulsion Systems |
NAICS | n/a |
SIC | 3732 - Boat Building And Repairing |
Sales | $100,000,000-$500,000,000 |
# of Employees | 1,100 |
Plant Area (Sq.Ft.) | 300,000 |
Annual Production | 93,000 Units |
Production Hrs. Annual | 6,240 |
Location (State) | OK |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,150,540 | 41,006,155 | kWh | $0.03 |
Electricity Demand | $728,426 | - | kW-months/year | - |
Natural Gas | $528,547 | 168,108 | MMBtu | $3.14 |
TOTAL ENERGY COSTS | $2,583,307 | |||
RECOMMENDED SAVINGS* | $1,627,161 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $83,828 |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Solid Waste (non-haz) | Administrative Changes | Ancillary Material Cost | Electricity Usage | Natural Gas | Solid Waste (non-haz) | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT |
Savings: $69,793 Cost: $76,000 |
$69,793 | 2,865,182 | - | - | - | - | - | - | - | - |
$69,793 2,865,182 kWh |
- - MMBtu |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2442 PREHEAT COMBUSTION AIR WITH WASTE HEAT |
Savings: $19,308 Cost: $57,400 |
- | - | $19,308 | 7,773 | - | - | - | - | - | - |
- - kWh |
$19,308 7,773 MMBtu |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $14,035 Cost: $6,760 |
$14,035 | 579,426 | - | - | - | - | - | - | - | - |
$14,035 579,426 kWh |
- - MMBtu |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2514 COVER OPEN TANKS |
Savings: $12,366 Cost: $7,500 |
- | - | $12,366 | 1,732 | - | - | - | - | - | - |
- - kWh |
$12,366 1,732 MMBtu |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.211 CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE |
Savings: $1,200,000 Cost: - |
- | - | - | - | - | - | - | - | $1,200,000 | - |
- - kWh |
- - MMBtu |
- - lb |
- - $ |
$1,200,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.321 OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES |
Savings: $200,000 Cost: - |
- | - | - | - | - | - | $200,000 | - | - | - |
- - kWh |
- - MMBtu |
- - lb |
$200,000 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.211 CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE |
Savings: $36,659 Cost: $100,000 |
- | - | - | - | - | - | - | - | $36,659 | - |
- - kWh |
- - MMBtu |
- - lb |
- - $ |
$36,659 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.5316 CONTRACT A WOOD PALLET RECYCLING COMPANY |
Savings: $75,000 Cost: - |
- | - | - | - | $75,000 | - | - | - | - | - |
- - kWh |
- - MMBtu |
$75,000 - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $1,627,161 Cost: $247,660 |
$83,828 | 3,444,608 | $31,674 | 9,505 | $75,000 | - | $200,000 | - | $1,236,659 | - | $83,828 3,444,608 kWh |
$31,674 9,505 MMBtu |
$75,000 - lb |
$200,000 - $ |
$1,236,659 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $83,828 Cost: $82,760 |
$83,828 | 3,444,608 | - | - | - | - | - | - | - | - | $83,828 3,444,608 kWh |
- - MMBtu |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Natural Gas | Solid Waste (non-haz) | Administrative Changes | Ancillary Material Cost | Electricity Usage | Natural Gas | Solid Waste (non-haz) | Administrative Changes | Ancillary Material Cost |