Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oklahoma State University |
---|---|
Assessment Year | 1999 |
Principal Product | Drilling Tools |
NAICS | n/a |
SIC | 3533 - Oil And Gas Field Machinery |
Sales | n/a |
# of Employees | 300 |
Plant Area (Sq.Ft.) | 240,000 |
Annual Production | 23,000 Pieces |
Production Hrs. Annual | 6,240 |
Location (State) | OK |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $467,532 | 14,842,321 | kWh | $0.03 |
Electricity Demand | $182,863 | - | kW-months/year | - |
Electricity Fees | $(-34,324) | - | $ | - |
Natural Gas | $155,359 | 40,685 | MMBtu | $3.82 |
TOTAL ENERGY COSTS | $824,370 | |||
RECOMMENDED SAVINGS* | $150,623 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $137,541 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Other Liquid (haz) | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Other Liquid (haz) | Personnel Changes | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | gal | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $4,785 Cost: $300 |
$1,323 | 108,148 | $3,462 | 208 | - | - | - | - | - | - |
$1,323 108,148 kWh |
$3,462 208 kW-months/year |
- - gal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $3,381 Cost: $2,100 |
$935 | 76,495 | $2,446 | 147 | - | - | - | - | - | - |
$935 76,495 kWh |
$2,446 147 kW-months/year |
- - gal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $934 Cost: $1,524 |
$934 | 29,015 | - | - | - | - | - | - | - | - |
$934 29,015 kWh |
- - kW-months/year |
- - gal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.322 ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL |
Savings: $129,375 Cost: - |
- | - | - | - | - | - | $129,375 | - | - | - |
- - kWh |
- - kW-months/year |
- - gal |
$129,375 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.211 CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE |
Savings: $6,000 Cost: - |
- | - | - | - | - | - | - | - | $6,000 | - |
- - kWh |
- - kW-months/year |
- - gal |
- - $ |
$6,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.6124 BURN WASTE OIL FOR HEAT |
Savings: $6,148 Cost: $10,470 |
- | - | - | - | $6,148 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$6,148 - gal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $150,623 Cost: $14,394 |
$3,192 | 213,658 | $5,908 | 355 | $6,148 | - | $129,375 | - | $6,000 | - | $3,192 213,658 kWh |
$5,908 355 kW-months/year |
$6,148 - gal |
$129,375 - $ |
$6,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $137,541 Cost: $2,400 |
$2,258 | 184,643 | $5,908 | 355 | - | - | $129,375 | - | - | - | $2,258 184,643 kWh |
$5,908 355 kW-months/year |
- - gal |
$129,375 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | gal | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Other Liquid (haz) | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Other Liquid (haz) | Personnel Changes | Administrative Changes |