Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oklahoma State University |
---|---|
Assessment Year | 2023 |
Principal Product | Lubricant and Grease |
NAICS | 324191 - Petroleum Lubricating Oil and Grease Manufacturing |
SIC | 2992 - Lubricating Oils And Greases |
Sales | $10,000,000-$50,000,000 |
# of Employees | 29 |
Plant Area (Sq.Ft.) | 65,000 |
Annual Production | 45,000 Tons |
Production Hrs. Annual | 4,550 |
Location (State) | KS |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $113,790 | 2,275,805 | kWh | $0.05 |
Electricity Demand | $116,350 | 6,453 | kW-months/year | $18.03 |
Electricity Fees | $36,724 | - | $ | - |
Natural Gas | $139,614 | 36,613 | MMBtu | $3.81 |
TOTAL ENERGY COSTS | $428,176 | |||
RECOMMENDED SAVINGS* | $75,042 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $35,994 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $15,211 Cost: $2,252 |
$15,211 | 304,217 | - | - | - | - | - | - | - | - |
$15,211 304,217 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $10,608 Cost: - |
- | - | - | - | - | - | - | - | $10,608 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$10,608 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $15,617 Cost: $218,400 |
$15,022 | 300,444 | $595 | 33 | - | - | - | - | - | - |
$15,022 300,444 kWh |
$595 33 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $4,300 Cost: $1,230 |
$4,300 | 85,995 | - | - | - | - | - | - | - | - |
$4,300 85,995 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT |
Savings: $8,026 Cost: $7,020 |
$8,026 | 160,524 | - | - | - | - | - | - | - | - |
$8,026 160,524 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $13,097 Cost: $11,114 |
$13,097 | 261,941 | - | - | - | - | - | - | - | - |
$13,097 261,941 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $4,263 Cost: $600 |
- | - | - | - | - | - | $4,263 | 1,119 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$4,263 1,119 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $3,920 Cost: $4,024 |
- | - | - | - | $3,920 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,920 - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $75,042 Cost: $244,640 |
$55,656 | 1,113,121 | $595 | 33 | $3,920 | - | $4,263 | 1,119 | $10,608 | - | $55,656 1,113,121 kWh |
$595 33 kW-months/year |
$3,920 - $ |
$4,263 1,119 MMBtu |
$10,608 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $35,994 Cost: $18,734 |
$21,123 | 422,465 | - | - | - | - | $4,263 | 1,119 | $10,608 | - | $21,123 422,465 kWh |
- - kW-months/year |
- - $ |
$4,263 1,119 MMBtu |
$10,608 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Administrative Changes |