IAC logo
IAC Assessment: OK1118
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: OK1118
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 2024
Principal Product Material handling equipment
NAICS 333923 - Overhead Traveling Crane, Hoist, and Monorail System Manufacturing
SIC 3429 - Hardware, Nec
Sales $10,000,000-$50,000,000
# of Employees 70
Plant Area (Sq.Ft.) 60,000
Annual Production 150 Tons
Production Hrs. Annual 2,340
Location (State) OK
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $84,193 604,570 kWh $0.14
Natural Gas $8,275 1,109 MMBtu $7.46
LPG $3,496 142 MMBtu $24.62
TOTAL ENERGY COSTS $97,096
RECOMMENDED SAVINGS* $41,592 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$20,756
Cost:
$102,600
$20,756 149,327 - - - - $20,756
149,327
kWh
-
-
MMBtu
-
-
$
02: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES Savings:
$772
Cost:
$450
$772 5,550 - - - - $772
5,550
kWh
-
-
MMBtu
-
-
$
03: 2.8112 COMBINE UTILITY METERS Savings:
$453
Cost:
$2,200
- - - - $453 - -
-
kWh
-
-
MMBtu
$453
-
$
04: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$816
Cost:
$4,683
- - - - $816 - -
-
kWh
-
-
MMBtu
$816
-
$
05: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS Savings:
$11,355
Cost:
$382,780
$6,782 48,790 $4,573 613 - - $6,782
48,790
kWh
$4,573
613
MMBtu
-
-
$
06: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS Savings:
$2,488
Cost:
$25,000
$2,085 15,000 $403 54 - - $2,085
15,000
kWh
$403
54
MMBtu
-
-
$
07: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$4,952
Cost:
$9,900
$4,952 35,622 - - - - $4,952
35,622
kWh
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$41,592
Cost:
$527,613
$35,347 254,289 $4,976 667 $1,269 - $35,347
254,289
kWh
$4,976
667
MMBtu
$1,269
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
MMBtu
-
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes