Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 2024
Principal Product Computer Data Storage Systems
NAICS 334112 - Computer Storage Device Manufacturing
SIC 3572 - Computer Storage Devices
Sales $100,000,000-$500,000,000
# of Employees 238
Plant Area (Sq.Ft.) 352,000
Annual Production 594,752 Units
Production Hrs. Annual 2,080
Location (State) OK
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $692,709 9,945,000 kWh $0.07
Electricity Demand $131,313 18,035 kW-months/year $7.28
Natural Gas $64,404 16,151 MMBtu $3.99
TOTAL ENERGY COSTS $893,242
RECOMMENDED SAVINGS* $95,463 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$81,240
Cost:
$643,500
$81,240 1,160,572 - - $81,240
1,160,572
kWh
-
-
MMBtu
02: 2.7493 USE DOUBLE OR TRIPLE GLAZED WINDOWS TO MAINTAIN HIGHER RELATIVE HUMIDITY AND TO REDUCE HEAT LOSSES Savings:
$2,279
Cost:
$62,775
$1,250 17,850 $1,029 258 $1,250
17,850
kWh
$1,029
258
MMBtu
03: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES Savings:
$2,363
Cost:
$1,900
$2,363 33,756 - - $2,363
33,756
kWh
-
-
MMBtu
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$1,664
Cost:
$8,000
- - $1,664 417 -
-
kWh
$1,664
417
MMBtu
05: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$7,917
Cost:
$55,440
$7,917 113,099 - - $7,917
113,099
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$95,463
Cost:
$771,615
$92,770 1,325,277 $2,693 675 $92,770
1,325,277
kWh
$2,693
675
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas