IAC logo
IAC Assessment: OK1153
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: OK1153
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 2025
Principal Product Hydro-Geothermal Heat Pump Systems
NAICS 333414 - Heating Equipment (except Warm Air Furnaces) Manufacturing
SIC 3433 - Heating Equipment, Except Electric
Sales $10,000,000-$50,000,000
# of Employees 500
Plant Area (Sq.Ft.) 244,850
Annual Production 7,750 Units
Production Hrs. Annual 4,160
Location (State) OK
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $409,053 7,158,280 kWh $0.06
Electricity Demand $172,482 16,910 kW-months/year $10.20
Natural Gas $55,839 13,016 MMBtu $4.29
TOTAL ENERGY COSTS $673,094
RECOMMENDED SAVINGS* $75,851 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Administrative Changes Electricity Usage Administrative Changes
$ kWh $ $
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$61,236
Cost:
$583,440
$61,236 1,074,308 - - $61,236
1,074,308
kWh
-
-
$
02: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$9,017
Cost:
$8,213
- - $9,017 - -
-
kWh
$9,017
-
$
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$4,794
Cost:
$5,610
$4,794 84,105 - - $4,794
84,105
kWh
-
-
$
04: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES Savings:
$804
Cost:
$900
$804 14,104 - - $804
14,104
kWh
-
-
$
TOTAL RECOMMENDED Savings:
$75,851
Cost:
$598,163
$66,834 1,172,517 $9,017 - $66,834
1,172,517
kWh
$9,017
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
$
Savings
Cost
$ kWh $ $
Electricity Usage Administrative Changes Electricity Usage Administrative Changes