Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 1998 |
Principal Product | Plastic bottles and preforms |
NAICS | n/a |
SIC | 3085 - Plastics Bottles |
Sales | $50,000,000-$100,000,000 |
# of Employees | 200 |
Plant Area (Sq.Ft.) | 320,000 |
Annual Production | 67,454,484 Pounds |
Production Hrs. Annual | 8,736 |
Location (State) | WA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,441,203 | 48,791,912 | kWh | $0.03 |
Electricity Demand | $408,589 | 92,531 | kW-months/year | $4.42 |
Electricity Fees | $20,020 | - | $ | - |
LPG | $4,194 | 549 | MMBtu | $7.64 |
TOTAL ENERGY COSTS | $1,990,932 | |||
RECOMMENDED SAVINGS* | $328,492 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $21,384 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.5311 RECOVER AND REUSE WASTE MATERIAL |
Savings: $173,800 Cost: $84,400 |
- | - | - | - | - | - | $(-8,400) | 554,000 | - | - | $182,200 | - |
- - kWh |
- - kW-months/year |
- - $ |
$(-8,400) 554,000 lb |
- - $ |
$182,200 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.441 INSTALL AUTOMATIC PACKING EQUIPMENT |
Savings: $107,110 Cost: $303,860 |
$(-1,010) | (-33,998) | $(-420) | (-95) | - | - | - | - | $108,540 | - | - | - |
$(-1,010) (-33,998) kWh |
$(-420) (-95) kW-months/year |
- - $ |
- - lb |
$108,540 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $7,050 Cost: $24,750 |
$(-40) | (-1,465) | $(-590) | (-134) | - | - | $7,680 | - | - | - | - | - |
$(-40) (-1,465) kWh |
$(-590) (-134) kW-months/year |
- - $ |
$7,680 - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $12,200 Cost: $2,450 |
$12,200 | 412,075 | - | - | - | - | - | - | - | - | - | - |
$12,200 412,075 kWh |
- - kW-months/year |
- - $ |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $9,184 Cost: $16,818 |
$7,498 | 253,810 | $1,686 | 383 | - | - | - | - | - | - | - | - |
$7,498 253,810 kWh |
$1,686 383 kW-months/year |
- - $ |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $19,148 Cost: $101,000 |
- | - | - | - | $19,148 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$19,148 - $ |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $328,492 Cost: $533,278 |
$18,648 | 630,422 | $676 | 154 | $19,148 | - | $(-720) | 554,000 | $108,540 | - | $182,200 | - | $18,648 630,422 kWh |
$676 154 kW-months/year |
$19,148 - $ |
$(-720) 554,000 lb |
$108,540 - $ |
$182,200 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $21,384 Cost: $19,268 |
$19,698 | 665,885 | $1,686 | 383 | - | - | - | - | - | - | - | - | $19,698 665,885 kWh |
$1,686 383 kW-months/year |
- - $ |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | Personnel Changes | Ancillary Material Cost |