Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 1999 |
Principal Product | ABS & CPVC Pipe |
NAICS | n/a |
SIC | 3084 - Plastics Pipe |
Sales | $10,000,000-$50,000,000 |
# of Employees | 19 |
Plant Area (Sq.Ft.) | 75,000 |
Annual Production | 24,162,868 Pounds |
Production Hrs. Annual | 7,200 |
Location (State) | OR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $209,578 | 6,164,420 | kWh | $0.03 |
Electricity Demand | $26,306 | 10,080 | kW-months/year | $2.61 |
Electricity Fees | $3,676 | - | $ | - |
Natural Gas | $2,215 | 417 | MMBtu | $5.31 |
TOTAL ENERGY COSTS | $248,443 | |||
RECOMMENDED SAVINGS* | $156,066 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $125,300 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Fees | Personnel Changes | Primary Raw Material | Electricity Usage | Electricity Fees | Personnel Changes | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.131 MODIFY PROCESS TO REDUCE MATERIAL USE/COST |
Savings: $93,600 Cost: $200,000 |
- | - | - | - | - | - | $93,600 | - |
- - kWh |
- - $ |
- - $ |
$93,600 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.126 INSTALL SENSORS TO DETECT DEFECTS |
Savings: $31,700 Cost: - |
- | - | - | - | $31,700 | - | - | - |
- - kWh |
- - $ |
$31,700 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2612 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION |
Savings: $27,050 Cost: $8,200 |
$27,050 | 796,014 | - | - | - | - | - | - |
$27,050 796,014 kWh |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $3,716 Cost: $10,200 |
- | - | $3,716 | - | - | - | - | - |
- - kWh |
$3,716 - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $156,066 Cost: $218,400 |
$27,050 | 796,014 | $3,716 | - | $31,700 | - | $93,600 | - | $27,050 796,014 kWh |
$3,716 - $ |
$31,700 - $ |
$93,600 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $125,300 Cost: $200,000 |
- | - | - | - | $31,700 | - | $93,600 | - | - - kWh |
- - $ |
$31,700 - $ |
$93,600 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Fees | Personnel Changes | Primary Raw Material | Electricity Usage | Electricity Fees | Personnel Changes | Primary Raw Material |