Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 1999 |
Principal Product | Particle Board |
NAICS | n/a |
SIC | 2493 - Reconstituted Wood Products |
Sales | $10,000,000-$50,000,000 |
# of Employees | 64 |
Plant Area (Sq.Ft.) | 96,570 |
Annual Production | 70,135 Thousand Feet |
Production Hrs. Annual | 8,400 |
Location (State) | ID |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $403,458 | 15,606,096 | kWh | $0.03 |
Electricity Demand | $66,000 | 314,652 | kW-months/year | $0.21 |
Electricity Fees | $(-2,622) | - | $ | - |
Natural Gas | $12,868 | 3,534 | MMBtu | $3.64 |
TOTAL ENERGY COSTS | $483,035 | |||
RECOMMENDED SAVINGS* | $313,459 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $78,343 |
#|Description |
Savings Cost |
Status | Electricity Usage | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Personnel Changes | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $40,560 Cost: $64,125 |
$40,560 | 1,568,875 | - | - | - | - | - | - |
$40,560 1,568,875 kWh |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES |
Savings: $36,220 Cost: $98,500 |
$5,840 | 225,674 | $2,300 | - | $22,000 | - | $6,080 | - |
$5,840 225,674 kWh |
$2,300 - $ |
$22,000 - $ |
$6,080 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4325 UPGRADE CONVEYORS |
Savings: $18,725 Cost: $46,000 |
$18,725 | 724,209 | - | - | - | - | - | - |
$18,725 724,209 kWh |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $13,088 Cost: $10,000 |
$13,088 | 506,155 | - | - | - | - | - | - |
$13,088 506,155 kWh |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,171 Cost: - |
$1,171 | 45,428 | - | - | - | - | - | - |
$1,171 45,428 kWh |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $24,695 Cost: $2,840 |
$24,695 | 955,158 | - | - | - | - | - | - |
$24,695 955,158 kWh |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.2176 INCREASE USE OF AUTOMATION |
Savings: $179,000 Cost: $42,000 |
- | - | $179,000 | - | - | - | - | - |
- - kWh |
$179,000 - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $313,459 Cost: $263,465 |
$104,079 | 4,025,499 | $181,300 | - | $22,000 | - | $6,080 | - | $104,079 4,025,499 kWh |
$181,300 - $ |
$22,000 - $ |
$6,080 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $78,343 Cost: $76,965 |
$78,343 | 3,030,188 | - | - | - | - | - | - | $78,343 3,030,188 kWh |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Personnel Changes | Administrative Changes | Ancillary Material Cost |