Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 2001 |
Principal Product | Liquid Fertilizer |
NAICS | n/a |
SIC | 2875 - Fertilizers, Mixing Only |
Sales | $1,000,000-$5,000,000 |
# of Employees | 7 |
Plant Area (Sq.Ft.) | 10,000 |
Annual Production | 219 Thousand Gallons |
Production Hrs. Annual | 4,480 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $45,756 | 873,382 | kWh | $0.05 |
Electricity Demand | $12,182 | 29,232 | kW-months/year | $0.42 |
Electricity Fees | $2,806 | - | $ | - |
LPG | $26,576 | 4,000 | MMBtu | $6.64 |
TOTAL ENERGY COSTS | $87,320 | |||
RECOMMENDED SAVINGS* | $29,898 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $18,398 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Primary Product | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $11,500 Cost: $10,500 |
- | - | - | - | - | - | $(-750) | - | $12,250 | - |
- - kWh |
- - kW-months/year |
- - $ |
$(-750) - $ |
$12,250 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $12,600 Cost: - |
$12,600 | 239,663 | - | - | - | - | - | - | - | - |
$12,600 239,663 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $2,007 Cost: - |
$1,474 | 28,125 | $533 | 108 | - | - | - | - | - | - |
$1,474 28,125 kWh |
$533 108 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $1,607 Cost: $3,763 |
$1,188 | 22,692 | $419 | 108 | - | - | - | - | - | - |
$1,188 22,692 kWh |
$419 108 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $2,184 Cost: - |
$1,838 | 35,096 | - | - | $29 | - | $317 | - | - | - |
$1,838 35,096 kWh |
- - kW-months/year |
$29 - $ |
$317 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $29,898 Cost: $14,263 |
$17,100 | 325,576 | $952 | 216 | $29 | - | $(-433) | - | $12,250 | - | $17,100 325,576 kWh |
$952 216 kW-months/year |
$29 - $ |
$(-433) - $ |
$12,250 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $18,398 Cost: $3,763 |
$17,100 | 325,576 | $952 | 216 | $29 | - | $317 | - | - | - | $17,100 325,576 kWh |
$952 216 kW-months/year |
$29 - $ |
$317 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Primary Product | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Primary Product |