Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 2001 |
Principal Product | Aluminum/Steel Boxes |
NAICS | n/a |
SIC | 3714 - Motor Vehicle Parts And Accessories |
Sales | $10,000,000-$50,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 70,000 |
Annual Production | 36,000 Pieces |
Production Hrs. Annual | 4,498 |
Location (State) | WA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $35,888 | 982,300 | kWh | $0.04 |
Electricity Demand | $12,260 | 2,652 | kW-months/year | $4.62 |
Electricity Fees | $2,555 | - | $ | - |
TOTAL ENERGY COSTS | $50,703 | |||
RECOMMENDED SAVINGS* | $88,355 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $84,826 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Ancillary Material Cost | Primary Product | Electricity Usage | Electricity Demand | Electricity Fees | Ancillary Material Cost | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.132 PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST |
Savings: $79,800 Cost: $30,700 |
- | - | - | - | - | - | $13,350 | - | $66,450 | - |
- - kWh |
- - kW-months/year |
- - $ |
$13,350 - $ |
$66,450 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $2,467 Cost: $2,100 |
- | - | - | - | $2,467 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,467 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,749 Cost: $1,700 |
$1,286 | 35,225 | $463 | 92 | - | - | - | - | - | - |
$1,286 35,225 kWh |
$463 92 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $3,277 Cost: $2,100 |
$2,408 | 65,975 | $869 | 174 | - | - | - | - | - | - |
$2,408 65,975 kWh |
$869 174 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.8112 COMBINE UTILITY METERS |
Savings: $1,062 Cost: $3,925 |
- | - | $(-985) | - | $2,047 | - | - | - | - | - |
- - kWh |
$(-985) - kW-months/year |
$2,047 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $88,355 Cost: $40,525 |
$3,694 | 101,200 | $347 | 266 | $4,514 | - | $13,350 | - | $66,450 | - | $3,694 101,200 kWh |
$347 266 kW-months/year |
$4,514 - $ |
$13,350 - $ |
$66,450 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $84,826 Cost: $34,500 |
$3,694 | 101,200 | $1,332 | 266 | - | - | $13,350 | - | $66,450 | - | $3,694 101,200 kWh |
$1,332 266 kW-months/year |
- - $ |
$13,350 - $ |
$66,450 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Ancillary Material Cost | Primary Product | Electricity Usage | Electricity Demand | Electricity Fees | Ancillary Material Cost | Primary Product |