Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 2001 |
Principal Product | Lumber |
NAICS | n/a |
SIC | 2421 - Sawmills And Planing Mills, General |
Sales | $50,000,000-$100,000,000 |
# of Employees | 155 |
Plant Area (Sq.Ft.) | 0 |
Annual Production | 167,129,000 Thousand Feet |
Production Hrs. Annual | 4,160 |
Location (State) | ID |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $510,940 | 18,054,400 | kWh | $0.03 |
Electricity Demand | $224,039 | 47,172 | kW-months/year | $4.75 |
TOTAL ENERGY COSTS | $734,979 | |||
RECOMMENDED SAVINGS* | $1,967,368 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $139,232 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Wood | Personnel Changes | Administrative Changes | Primary Product | Increase in Production | Electricity Usage | Electricity Demand | Wood | Personnel Changes | Administrative Changes | Primary Product | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $76,739 Cost: $50,000 |
- | - | $76,739 | 30,000 | - | - | - | - | - | - | - | - | - | - |
- - kWh |
$76,739 30,000 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $6,160 Cost: $6,000 |
$4,140 | 146,100 | $2,020 | 425 | - | - | - | - | - | - | - | - | - | - |
$4,140 146,100 kWh |
$2,020 425 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $56,333 Cost: $68,000 |
$56,333 | 1,990,553 | - | - | - | - | - | - | - | - | - | - | - | - |
$56,333 1,990,553 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $560,470 Cost: $690,000 |
- | - | - | - | $20,470 | 10,235 | - | - | - | - | - | - | $540,000 | - |
- - kWh |
- - kW-months/year |
$20,470 10,235 MMBtu |
- - $ |
- - $ |
- - $ |
$540,000 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.126 INSTALL SENSORS TO DETECT DEFECTS |
Savings: $524,500 Cost: $2,000,000 |
- | - | - | - | - | - | $216,000 | - | $(-150,000) | - | - | - | $458,500 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$216,000 - $ |
$(-150,000) - $ |
- - $ |
$458,500 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.122 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS |
Savings: $473,166 Cost: $120,000 |
- | - | - | - | - | - | - | - | - | - | - | - | $473,166 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
$473,166 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.322 ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL |
Savings: $270,000 Cost: $50,000 |
- | - | - | - | - | - | - | - | - | - | $270,000 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
$270,000 - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $1,967,368 Cost: $2,984,000 |
$60,473 | 2,136,653 | $78,759 | 30,425 | $20,470 | 10,235 | $216,000 | - | $(-150,000) | - | $270,000 | - | $1,471,666 | - | $60,473 2,136,653 kWh |
$78,759 30,425 kW-months/year |
$20,470 10,235 MMBtu |
$216,000 - $ |
$(-150,000) - $ |
$270,000 - $ |
$1,471,666 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $139,232 Cost: $124,000 |
$60,473 | 2,136,653 | $78,759 | 30,425 | - | - | - | - | - | - | - | - | - | - | $60,473 2,136,653 kWh |
$78,759 30,425 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Wood | Personnel Changes | Administrative Changes | Primary Product | Increase in Production | Electricity Usage | Electricity Demand | Wood | Personnel Changes | Administrative Changes | Primary Product | Increase in Production |