Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 2002 |
Principal Product | camping trailers |
NAICS | n/a |
SIC | 3792 - Travel Trailers And Campers |
Sales | $1,000,000-$5,000,000 |
# of Employees | 24 |
Plant Area (Sq.Ft.) | 19,000 |
Annual Production | 300 Pieces |
Production Hrs. Annual | 2,442 |
Location (State) | OR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $4,050 | 69,820 | kWh | $0.06 |
Electricity Demand | $488 | 336 | kW-months/year | $1.45 |
TOTAL ENERGY COSTS | $4,538 | |||
RECOMMENDED SAVINGS* | $1,620,420 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $214,220 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Primary Raw Material | Primary Product | Increase in Production | Electricity Usage | Electricity Demand | Personnel Changes | Primary Raw Material | Primary Product | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.511 EXPAND OPERATIONS INTO UNUSED SPACE |
Savings: $10,000 Cost: $1,200 |
- | - | - | - | - | - | - | - | - | - | $10,000 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
$10,000 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.432 CROSS-TRAIN PERSONNEL TO AVOID LOST TIME |
Savings: $214,000 Cost: $5,000 |
- | - | - | - | - | - | - | - | - | - | $214,000 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
$214,000 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 4.431 TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY |
Savings: $142,400 Cost: $25,000 |
- | - | - | - | - | - | - | - | $142,400 | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - $ |
$142,400 - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.423 MOVE PRODUCT USING MECHANICAL MEANS |
Savings: $3,500 Cost: $2,800 |
- | - | - | - | - | - | - | - | $3,500 | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - $ |
$3,500 - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.426 MODIFY WORKLOAD |
Savings: $1,250,300 Cost: $29,300 |
- | - | - | - | $78,200 | - | $689,200 | - | - | - | $482,900 | - |
- - kWh |
- - kW-months/year |
$78,200 - $ |
$689,200 - $ |
- - $ |
$482,900 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $220 Cost: $50 |
$50 | 1,036 | $170 | 56 | - | - | - | - | - | - | - | - |
$50 1,036 kWh |
$170 56 kW-months/year |
- - $ |
- - $ |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $1,620,420 Cost: $63,350 |
$50 | 1,036 | $170 | 56 | $78,200 | - | $689,200 | - | $145,900 | - | $706,900 | - | $50 1,036 kWh |
$170 56 kW-months/year |
$78,200 - $ |
$689,200 - $ |
$145,900 - $ |
$706,900 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $214,220 Cost: $5,050 |
$50 | 1,036 | $170 | 56 | - | - | - | - | - | - | $214,000 | - | $50 1,036 kWh |
$170 56 kW-months/year |
- - $ |
- - $ |
- - $ |
$214,000 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Primary Raw Material | Primary Product | Increase in Production | Electricity Usage | Electricity Demand | Personnel Changes | Primary Raw Material | Primary Product | Increase in Production |