Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oregon State University
Assessment Year 2009
Principal Product Printed paper products
NAICS 323111 - Commercial Printing (except Screen and Books)
SIC 2752 - Commercial Printing, Lithographic
Sales $100,000,000-$500,000,000
# of Employees 102
Plant Area (Sq.Ft.) 130,000
Annual Production 198,000,000 Pieces
Production Hrs. Annual 4,500
Location (State) OR
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $165,405 4,816,800 kWh $0.03
Electricity Demand $73,416 11,765 kW-months/year $6.24
Electricity Fees $672 - $ -
Natural Gas $18,731 16,156 MMBtu $1.16
TOTAL ENERGY COSTS $258,224
RECOMMENDED SAVINGS* $12,400 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$2,100
Cost:
-
$2,100 62,000 - - $2,100
62,000
kWh
-
-
MMBtu
02: 2.4224 UPGRADE CONTROLS ON COMPRESSORS Savings:
$2,800
Cost:
$400
$2,800 78 - - $2,800
78
kWh
-
-
MMBtu
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$3,000
Cost:
$3,000
$3,000 72 - - $3,000
72
kWh
-
-
MMBtu
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$3,500
Cost:
$15,100
- - $3,500 311 -
-
kWh
$3,500
311
MMBtu
05: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$1,000
Cost:
$8,600
$1,000 22 - - $1,000
22
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$12,400
Cost:
$27,100
$8,900 62,172 $3,500 311 $8,900
62,172
kWh
$3,500
311
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas