Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oregon State University
Assessment Year 2012
Principal Product Steel
NAICS 331110 - Iron and Steel Mills and Ferroalloy Manufacturing
SIC 3312 - Blast Furnaces And Steel Mills
Sales $1,000,000-$5,000,000
# of Employees 150
Plant Area (Sq.Ft.) 40,000
Annual Production 10,400,000 Pounds
Production Hrs. Annual 6,240
Location (State) WA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $232,388 4,950,030 kWh $0.05
Electricity Demand $163,636 26,345 kW-months/year $6.21
Electricity Fees $24,072 - $ -
TOTAL ENERGY COSTS $420,096
RECOMMENDED SAVINGS* $440,700 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Solid Waste (non-haz) Ancillary Material Cost Electricity Usage Electricity Demand Solid Waste (non-haz) Ancillary Material Cost
$ kWh $ kW-months/year $ lb $ $
01: 3.5221 RECYCLE CASTING SAND Savings:
$437,377
Cost:
$71,170
- - - - $20,000 5,004,520 $417,377 - -
-
kWh
-
-
kW-months/year
$20,000
5,004,520
lb
$417,377
-
$
02: 2.4224 UPGRADE CONTROLS ON COMPRESSORS Savings:
$2,289
Cost:
$1,015
$1,089 23,197 $1,200 177 - - - - $1,089
23,197
kWh
$1,200
177
kW-months/year
-
-
lb
-
-
$
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,034
Cost:
$1,534
$617 13,142 $417 62 - - - - $617
13,142
kWh
$417
62
kW-months/year
-
-
lb
-
-
$
TOTAL RECOMMENDED Savings:
$440,700
Cost:
$73,719
$1,706 36,339 $1,617 239 $20,000 5,004,520 $417,377 - $1,706
36,339
kWh
$1,617
239
kW-months/year
$20,000
5,004,520
lb
$417,377
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
lb
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ lb $ $
Electricity Usage Electricity Demand Solid Waste (non-haz) Ancillary Material Cost Electricity Usage Electricity Demand Solid Waste (non-haz) Ancillary Material Cost