IAC Center | Oregon State University |
---|---|
Assessment Year | 2014 |
Principal Product | Malted Barley |
NAICS | 311213 - Malt Manufacturing |
SIC | 2083 - Malt |
Sales | $50,000,000-$100,000,000 |
# of Employees | 105 |
Plant Area (Sq.Ft.) | 75,000 |
Annual Production | 132,000 Tons |
Production Hrs. Annual | 7,488 |
Location (State) | WA |
View Case Study |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $949,062 | 20,238,230 | kWh | $0.05 |
Electricity Demand | $240,683 | 40,519 | kW-months/year | $5.94 |
Electricity Fees | $36,001 | - | $ | - |
Natural Gas | $2,056,903 | 380,908 | MMBtu | $5.40 |
TOTAL ENERGY COSTS | $3,282,649 | |||
RECOMMENDED SAVINGS* | $657,757 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $619,894 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.5121 REDESIGN FLOW TO MINIMIZE MASS TRANSFER LENGTH |
Savings: $37,907 Cost: $21,000 |
$32,256 | 694,434 | $5,651 | 951 | - | - | - | - |
$32,256 694,434 kWh |
$5,651 951 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2443 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR |
Savings: $37,863 Cost: $38,930 |
- | - | - | - | $37,863 | 7,012 | - | - |
- - kWh |
- - kW-months/year |
$37,863 7,012 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.4115 RECOVER AND REUSE COOLING WATER |
Savings: $58,681 Cost: $3,764 |
$49,934 | 1,075,012 | $8,747 | 1,473 | - | - | - | - |
$49,934 1,075,012 kWh |
$8,747 1,473 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1224 REPLACE BOILER |
Savings: $523,306 Cost: $3,403,664 |
- | - | - | - | $233,306 | 43,205 | $290,000 | - |
- - kWh |
- - kW-months/year |
$233,306 43,205 MMBtu |
$290,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $657,757 Cost: $3,467,358 |
$82,190 | 1,769,446 | $14,398 | 2,424 | $271,169 | 50,217 | $290,000 | - | $82,190 1,769,446 kWh |
$14,398 2,424 kW-months/year |
$271,169 50,217 MMBtu |
$290,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $619,894 Cost: $3,428,428 |
$82,190 | 1,769,446 | $14,398 | 2,424 | $233,306 | 43,205 | $290,000 | - | $82,190 1,769,446 kWh |
$14,398 2,424 kW-months/year |
$233,306 43,205 MMBtu |
$290,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes |