Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 2017 |
Principal Product | Automotive Batteries |
NAICS | 335911 - Storage Battery Manufacturing |
SIC | 3691 - Storage Batteries |
Sales | $1,000,000-$5,000,000 |
# of Employees | 250 |
Plant Area (Sq.Ft.) | 204,000 |
Annual Production | 5,000,000 Units |
Production Hrs. Annual | 8,760 |
Location (State) | OR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,608,531 | 30,255,314 | kWh | $0.05 |
Electricity Demand | $338,695 | 57,503 | kW-months/year | $5.89 |
Natural Gas | $200,099 | 41,266 | MMBtu | $4.85 |
TOTAL ENERGY COSTS | $2,147,325 | |||
RECOMMENDED SAVINGS* | $220,341 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Primary Raw Material | Ancillary Material Cost | By-product Production | Increase in Production | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Primary Raw Material | Ancillary Material Cost | By-product Production | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1133 ADJUST BURNERS FOR EFFICIENT OPERATION |
Savings: $2,090 Cost: $600 |
- | - | - | - | $2,090 | 358 | - | - | - | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,090 358 MMBtu |
- - $ |
- - $ |
- - $ |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $2,967 Cost: $2,000 |
$2,001 | 47,760 | $204 | 35 | - | - | - | - | $232 | - | - | - | $530 | - | - | - | - | - |
$2,001 47,760 kWh |
$204 35 kW-months/year |
- - MMBtu |
- - $ |
$232 - $ |
- - $ |
$530 - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES |
Savings: $205,629 Cost: $340,000 |
$(-13,846) | (-328,882) | - | - | - | - | - | - | $2,550 | - | - | - | $6,000 | - | - | - | $210,925 | - |
$(-13,846) (-328,882) kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$2,550 - $ |
- - $ |
$6,000 - $ |
- - $ |
$210,925 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.131 MODIFY PROCESS TO REDUCE MATERIAL USE/COST |
Savings: $3,195 Cost: $5,650 |
- | - | - | - | $65 | 11 | $3,208 | - | - | - | $3,564 | - | - | - | $(-3,642) | - | - | - |
- - kWh |
- - kW-months/year |
$65 11 MMBtu |
$3,208 - $ |
- - $ |
$3,564 - $ |
- - $ |
$(-3,642) - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4324 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT |
Savings: $6,460 Cost: $16,124 |
$6,460 | 153,443 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
$6,460 153,443 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $220,341 Cost: $364,374 |
$(-5,385) | (-127,679) | $204 | 35 | $2,155 | 369 | $3,208 | - | $2,782 | - | $3,564 | - | $6,530 | - | $(-3,642) | - | $210,925 | - | $(-5,385) (-127,679) kWh |
$204 35 kW-months/year |
$2,155 369 MMBtu |
$3,208 - $ |
$2,782 - $ |
$3,564 - $ |
$6,530 - $ |
$(-3,642) - $ |
$210,925 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Primary Raw Material | Ancillary Material Cost | By-product Production | Increase in Production | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Primary Raw Material | Ancillary Material Cost | By-product Production | Increase in Production |