Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 2017 |
Principal Product | Juice and Puree |
NAICS | 311411 - Frozen Fruit, Juice, and Vegetable Manufacturing |
SIC | 2037 - Frozen Fruits And Vegetables |
Sales | $50,000,000-$100,000,000 |
# of Employees | 110 |
Plant Area (Sq.Ft.) | 44,227 |
Annual Production | 136 Units |
Production Hrs. Annual | 7,296 |
Location (State) | OR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $184,623 | 2,298,203 | kWh | $0.08 |
Electricity Demand | $17,509 | 3,070 | kW-months/year | $5.70 |
Natural Gas | $242,268 | 70,640 | MMBtu | $3.43 |
TOTAL ENERGY COSTS | $716,639 | |||
RECOMMENDED SAVINGS* | $535,529 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Usage | Water Disposal | Personnel Changes | Primary Product | Increase in Production | Electricity Usage | Electricity Demand | Natural Gas | Water Usage | Water Disposal | Personnel Changes | Primary Product | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | Tgal | $ | $ | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $190,250 Cost: $7,842 |
- | - | - | - | $(-2,950) | (-844) | - | - | - | - | - | - | $193,200 | - | - | - |
- - kWh |
- - kW-months/year |
$(-2,950) (-844) MMBtu |
- - Tgal |
- - Tgal |
- - $ |
$193,200 - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE |
Savings: $78,503 Cost: $7,018 |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | $78,503 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
- - $ |
$78,503 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 4.651 INSTALL BACK-UP EQUIPMENT |
Savings: $219,130 Cost: $45,000 |
- | - | - | - | - | - | - | - | - | - | $219,130 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
$219,130 - $ |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $29,962 Cost: $12,100 |
- | - | - | - | - | - | - | - | - | - | $29,962 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
$29,962 - $ |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $9,605 Cost: $10,606 |
$9,043 | 130,760 | $562 | 111 | - | - | - | - | - | - | - | - | - | - | - | - |
$9,043 130,760 kWh |
$562 111 kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.4151 MINIMIZE WATER USAGE |
Savings: $8,079 Cost: $15,125 |
- | - | - | - | - | - | $3,403 | 1,562 | $4,676 | 1,562 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$3,403 1,562 Tgal |
$4,676 1,562 Tgal |
- - $ |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $535,529 Cost: $97,691 |
$9,043 | 130,760 | $562 | 111 | $(-2,950) | (-844) | $3,403 | 1,562 | $4,676 | 1,562 | $249,092 | - | $193,200 | - | $78,503 | - | $9,043 130,760 kWh |
$562 111 kW-months/year |
$(-2,950) (-844) MMBtu |
$3,403 1,562 Tgal |
$4,676 1,562 Tgal |
$249,092 - $ |
$193,200 - $ |
$78,503 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | Tgal | $ | $ | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Usage | Water Disposal | Personnel Changes | Primary Product | Increase in Production | Electricity Usage | Electricity Demand | Natural Gas | Water Usage | Water Disposal | Personnel Changes | Primary Product | Increase in Production |