Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 2018 |
Principal Product | Ships and Boats |
NAICS | 332710 - Machine Shops |
SIC | 3599 - Industrial Machinery, Nec |
Sales | $100,000,000-$500,000,000 |
# of Employees | 500 |
Plant Area (Sq.Ft.) | 2,778,000 |
Annual Production | 50 Units |
Production Hrs. Annual | 8,592 |
Location (State) | OR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $2,196,931 | 36,457,079 | kWh | $0.06 |
Electricity Demand | $284,763 | 82,083 | kW-months/year | $3.47 |
Electricity Fees | $369,600 | - | $ | - |
Natural Gas | $398,021 | 92,618 | MMBtu | $4.30 |
TOTAL ENERGY COSTS | $4,055,757 | |||
RECOMMENDED SAVINGS* | $267,981 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $230,140 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.4145 USE MAGNETIC TECHNOLOGY TO TREAT WATER |
Savings: $201,762 Cost: $50,000 |
- | - | - | - | - | - | $134,851 | 10,037 | $66,911 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$134,851 10,037 Tgal |
$66,911 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $18,460 Cost: $45,600 |
$18,460 | 315,932 | - | - | - | - | - | - | - | - |
$18,460 315,932 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $25,653 Cost: $51,599 |
- | - | - | - | $25,653 | 6,676 | - | - | - | - |
- - kWh |
- - kW-months/year |
$25,653 6,676 MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $19,381 Cost: $19,381 |
- | - | - | - | $19,381 | 5,044 | - | - | - | - |
- - kWh |
- - kW-months/year |
$19,381 5,044 MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $2,725 Cost: $250 |
$2,060 | 35,262 | $665 | 348 | - | - | - | - | - | - |
$2,060 35,262 kWh |
$665 348 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $267,981 Cost: $166,830 |
$20,520 | 351,194 | $665 | 348 | $45,034 | 11,720 | $134,851 | 10,037 | $66,911 | - | $20,520 351,194 kWh |
$665 348 kW-months/year |
$45,034 11,720 MMBtu |
$134,851 10,037 Tgal |
$66,911 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $230,140 Cost: $101,849 |
$2,060 | 35,262 | $665 | 348 | $25,653 | 6,676 | $134,851 | 10,037 | $66,911 | - | $2,060 35,262 kWh |
$665 348 kW-months/year |
$25,653 6,676 MMBtu |
$134,851 10,037 Tgal |
$66,911 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes |