IAC logo
IAC Assessment: OR0743
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: OR0743
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oregon State University
Assessment Year 2021
Principal Product Hemp seed
NAICS 339999 - All Other Miscellaneous Manufacturing
SIC 3999 - Manufacturing Industries, Nec
Sales $10,000,000-$50,000,000
# of Employees 36
Plant Area (Sq.Ft.) 275,000
Annual Production 1,000,000,000 Pieces
Production Hrs. Annual 6,132
Location (State) OR
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $378,206 7,486,837 kWh $0.05
Electricity Demand $182,024 18,942 kW-months/year $9.61
Electricity Fees $80,647 - $ -
TOTAL ENERGY COSTS $640,877
RECOMMENDED SAVINGS* $80,986 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $80,986
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Personnel Changes Administrative Changes Ancillary Material Cost Electricity Usage Electricity Demand Electricity Fees Personnel Changes Administrative Changes Ancillary Material Cost
$ kWh $ kW-months/year $ $ $ $ $ $ $ $
01: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE Savings:
$46,625
Cost:
-
$11,522 - $15,698 - $(-2,400) - - - $21,805 - - - $11,522
-
kWh
$15,698
-
kW-months/year
$(-2,400)
-
$
-
-
$
$21,805
-
$
-
-
$
02: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT Savings:
$4,808
Cost:
$8,548
$25,734 490,872 - - - - $(-16,541) - - - $(-4,385) - $25,734
490,872
kWh
-
-
kW-months/year
-
-
$
$(-16,541)
-
$
-
-
$
$(-4,385)
-
$
03: 2.3112 STORE HEATED/ COOLED WATER FOR USE DURING PEAK DEMAND PERIODS Savings:
$29,553
Cost:
$281,475
- - $29,553 - - - - - - - - - -
-
kWh
$29,553
-
kW-months/year
-
-
$
-
-
$
-
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$80,986
Cost:
$290,023
$37,256 490,872 $45,251 - $(-2,400) - $(-16,541) - $21,805 - $(-4,385) - $37,256
490,872
kWh
$45,251
-
kW-months/year
$(-2,400)
-
$
$(-16,541)
-
$
$21,805
-
$
$(-4,385)
-
$
TOTAL IMPLEMENTED Savings:
$80,986
Cost:
$290,023
$37,256 490,872 $45,251 - $(-2,400) - $(-16,541) - $21,805 - $(-4,385) - $37,256
490,872
kWh
$45,251
-
kW-months/year
$(-2,400)
-
$
$(-16,541)
-
$
$21,805
-
$
$(-4,385)
-
$
Savings
Cost
$ kWh $ kW-months/year $ $ $ $ $ $ $ $
Electricity Usage Electricity Demand Electricity Fees Personnel Changes Administrative Changes Ancillary Material Cost Electricity Usage Electricity Demand Electricity Fees Personnel Changes Administrative Changes Ancillary Material Cost