Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oregon State University |
---|---|
Assessment Year | 2023 |
Principal Product | Lumber |
NAICS | 321999 - All Other Miscellaneous Wood Product Manufacturing |
SIC | 2499 - Wood Products, Nec |
Sales | $1,000,000-$5,000,000 |
# of Employees | 29 |
Plant Area (Sq.Ft.) | 21,780,000 |
Annual Production | 18,000 Thousand Feet |
Production Hrs. Annual | 2,040 |
Location (State) | OR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $142,997 | 2,269,800 | kWh | $0.06 |
Electricity Demand | $38,760 | 6,460 | kW-months/year | $6.00 |
Electricity Fees | $3,301 | - | $ | - |
Natural Gas | $254,857 | 42,138 | MMBtu | $6.05 |
TOTAL ENERGY COSTS | $444,688 | |||
RECOMMENDED SAVINGS* | $497,551 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $473,163 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Primary Product | Electricity Usage | Electricity Demand | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,793 Cost: - |
$1,284 | 20,378 | $509 | 85 | - | - |
$1,284 20,378 kWh |
$509 85 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.661 LEVEL ZERO – INSTALL CONTROL SYSTEMS FOR EXISTING EQUIPMENT |
Savings: $172,773 Cost: $37,200 |
- | - | - | - | $172,773 | - |
- - kWh |
- - kW-months/year |
$172,773 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $300,390 Cost: $200,000 |
- | - | - | - | $300,390 | - |
- - kWh |
- - kW-months/year |
$300,390 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $17,167 Cost: $14,238 |
$11,003 | 174,651 | $6,164 | 1,027 | - | - |
$11,003 174,651 kWh |
$6,164 1,027 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $5,428 Cost: $5,428 |
$4,184 | 66,413 | $1,244 | 207 | - | - |
$4,184 66,413 kWh |
$1,244 207 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $497,551 Cost: $256,866 |
$16,471 | 261,442 | $7,917 | 1,319 | $473,163 | - | $16,471 261,442 kWh |
$7,917 1,319 kW-months/year |
$473,163 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $473,163 Cost: $237,200 |
- | - | - | - | $473,163 | - | - - kWh |
- - kW-months/year |
$473,163 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Primary Product | Electricity Usage | Electricity Demand | Primary Product |